AT32UC3L064_11 ATMEL [ATMEL Corporation], AT32UC3L064_11 Datasheet - Page 79

no-image

AT32UC3L064_11

Manufacturer Part Number
AT32UC3L064_11
Description
32-bit Atmel AVR Microcontroller
Manufacturer
ATMEL [ATMEL Corporation]
Datasheet
10. Errata
10.1
10.1.1
10.1.2
10.1.3
32099HS–12/2011
Rev. E
Processor and Architecture
FLASHCDW
Power Manager
1. Hardware breakpoints may corrupt MAC results
2. Privilege violation when using interrupts in application mode with protected system
1. Flash self programming may fail in one wait state mode
1. Clock sources will not be stopped in Static mode if the difference between CPU and
2. Clock Failure Detector (CFD) can be issued while turning off the CFD
3. Sleepwalking in idle and frozen sleep mode will mask all other PB clocks
Hardware breakpoints on MAC instructions may corrupt the destination register of the MAC
instruction.
Fix/Workaround
Place breakpoints on earlier or later instructions.
stack
If the system stack is protected by the MPU and an interrupt occurs in application mode, an
MPU DTLB exception will occur.
Fix/Workaround
Make a DTLB Protection (Write) exception handler which permits the interrupt request to be
handled in privileged mode.
Writes in flash and user pages may fail if executing code is located in address space
mapped to flash, and the flash controller is configured in one wait state mode (the Flash
Wait State bit in the Flash Control Register (FCR.FWS) is one).
Fix/Workaround
Solution 1: Configure the flash controller in zero wait state mode (FCR.FWS=0).
Solution 2: Configure the HMATRIX master 1 (CPU Instruction) to use the unlimited burst
length transfer mode (MCFG1.ULBT=0), and the HMATRIX slave 0 (FLASHCDW) to use
the maximum slot cycle limit (SCFG0.SLOT_CYCLE=255).
PBx division factor is larger than 4
If the division factor between the CPU/HSB and PBx frequencies is more than 4 when enter-
ing a sleep mode where the system RC oscillator (RCSYS) is turned off, the high speed
clock sources will not be turned off. This will result in a significantly higher power consump-
tion during the sleep mode.
Fix/Workaround
Before going to sleep modes where RCSYS is stopped, make sure the division factor
between CPU/HSB and PBx frequencies is less than or equal to 4.
While turning off the CFD, the CFD bit in the Status Register (SR) can be set. This will
change the main clock source to RCSYS.
Fix/Workaround
Solution 1: Enable CFD interrupt. If CFD interrupt is issues after turning off the CFD, switch
back to original main clock source.
Solution 2: Only turn off the CFD while running the main clock on RCSYS.