EDD25163HBH-6ELS-F ELPIDA [Elpida Memory], EDD25163HBH-6ELS-F Datasheet - Page 19

no-image

EDD25163HBH-6ELS-F

Manufacturer Part Number
EDD25163HBH-6ELS-F
Description
Manufacturer
ELPIDA [Elpida Memory]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EDD25163HBH-6ELS-F
Manufacturer:
ELPIDA
Quantity:
17 580
Part Number:
EDD25163HBH-6ELS-F
Manufacturer:
CITIZEN
Quantity:
4 634
Current state
Write with auto pre-
charge*
Remark: H: VIH. L: VIL. : Don’t care.
Notes: 1. The DDR Mobile RAM is in "Precharging" state for tRP after precharge command is issued.
Preliminary Data Sheet E1434E30 (Ver. 3.0)
From command
Read w/AP
Write w/AP
1
2. The DDR Mobile RAM reaches "IDLE" state tRP after precharge command is issued.
3. The DDR Mobile RAM is in "Refresh" state for tRFC after auto-refresh command is issued.
4. The DDR Mobile RAM is in "Activating" state for tRCD after ACT command is issued.
5. The DDR Mobile RAM is in "Active" state after "Activating" is completed.
6. The DDR Mobile RAM is in "READ" state until burst data have been output and DQ output circuits are
7. The DDR Mobile RAM is in "READ with auto precharge" from READA command until burst data has been
8. The DDR Mobile RAM is in "WRITE" state from WRIT command to the last burst data are input.
9. The DDR Mobile RAM is in "Write recovering" for tWR after the last data are input.
10. The DDR Mobile RAM is in "Write with auto precharge" until tWR after the last data has been input.
11. This command may be issued for other banks, depending on the state of the banks.
12. All banks must be in "IDLE".
13. Before executing a write command to stop the preceding burst read operation, BST command must be
14. The DDR Mobile RAM supports the concurrent auto precharge feature, a read with auto precharge or a
turned off.
output and DQ output circuits are turned off.
issued.
write with auto precharge, can be followed by any command to the other banks, as long as that command
does not interrupt the read or write data transfer, and all other related limitations apply (e.g. contention
between READ data and WRITE data must be avoided.)
The minimum delay from a read or write command with auto precharge, to a command to a different bank,
is summarized below.
/CS
H
L
L
L
L
L
L
L
To command (different bank, non-
interrupting command)
Read or Read w/AP
Write or Write w/AP
Precharge or Activate
Read or Read w/AP
Write or Write w/AP
Precharge or Activate
/RAS /CAS /WE
H
H
H
H
L
L
L
H
H
L
L
H
H
L
H
L
H
L
H
L
Address
BA, CA, A10
BA, CA, A10
BA, RA
BA, A10
19
Minimum delay
(Concurrent AP supported)
BL/2
CL (rounded up)+ (BL/2)
1
1 + (BL/2) + tWTR
BL/2
1
Command
WRIT/WRIT A
ACT
PRE, PALL
DESL
NOP
BST
READ/READA
EDD25163HBH-LS
Operation
NOP
NOP
ILLEGAL
ILLEGAL*
ILLEGAL*
ILLEGAL*
ILLEGAL*
ILLEGAL
14
14
11, 14
11, 14
Units
tCK
tCK
tCK
tCK
tCK
tCK

Related parts for EDD25163HBH-6ELS-F