60 •
7.30
7.31
The EM65571 has a built-in discharge circuit, which discharges electricity from capacitors
for stability of power sources (V0~V4).
The discharge circuit is valid, while the DIS register is set to “1”. When the built-in power
supply is used, it should be set DIS=”1” after the power source is turned off (DCON,
AMPON) = (0, 0). Both the built-in power source and the external power source (V0~V4,
VOUT) should not be turned off while DIS= ”1”.
Setting RESB pin to “L” initializes the EM65571. Normally, the RESB pin is initialized
together with the MPU by connecting to the reset pin of the MPU. When power is ON, be
sure to make RESB=”L”.
Discharge Circuit
Initialization
Register in electronic volume
Display Normal/Reverse
Common shift direction
Display starting line
Gradation Palette 0
Gradation Palette 1
Gradation Palette 2
Gradation Palette 3
Gradation Palette 4
Gradation Palette 5
Gradation Palette 6
Gradation Palette 7
Gradation Palette 8
Data SWAP Mode
Display ON/OFF
Increment mode
n-line alternate
Power Supply
Display mode
Display RAM
Display duty
(BF1, BF0)
REF mode
X Address
Y Address
Bias ratio
ITEM
(This specification is subject to change without further notice)
COM0 → COM127, COMA, COMB
Gradation display mode
Set at the first line (0H)
(0, 0, 0, 0, 0, 0, 0)
Every frame unit
Product Specification (V1.0) 08.04.2005
Increment OFF
(0, 0, 0, 0, 0, 0)
(0, 0, 0, 0, 1, 0)
(0, 0, 0, 0, 1, 1)
(0, 0, 0, 1, 0, 1)
(0, 0, 0, 1, 1, 0)
(0, 0, 1, 0, 0, 0)
(0, 0, 1, 0, 0, 1)
(0, 0, 1, 0, 1, 1)
(0, 0, 1, 1, 0, 0)
Initial Value
Display OFF
1/13 bias
Not fixed
00H set
00H set
Normal
Normal
(0, 0)
OFF
OFF
1/10