EDS11-158C FUJI [Fuji Electric], EDS11-158C Datasheet - Page 4

no-image

EDS11-158C

Manufacturer Part Number
EDS11-158C
Description
Manufacturer
FUJI [Fuji Electric]
Datasheet
4
6.1 Number of alarm setting points
• Up to 3 points (depends on number of DO)
6.2 Alarm type
• Process value (upper limit/lower limit, absolute/devia-
6.3 Heater burnout alarm function
(1) Detectable range:
(2) Detected current resolution:
(3) Setting resolution:
(4) Hysteresis:
7.1 RS-485 interface
(1) Number of points: 1 point
(2) Physical specifications: EIA RS485
(3) Protocol:
(4) Communication method:
(5) Code type:
(6) Communication rate:
(7) Connection status:
(8) Communication distance:
• Memory protection:
• Method:
(1) Operating ambient temperature:
(2) Storage temperature:
(3) Operating/storage ambient humidity:
(4) Warm-up time:
(5) Vibration:
(6) Impact:
6. Alarm function
tion, range), main unit error, etc.
(non-excitation, delay, latch, timer function option provided)
7. Communication function
8. Processing at power failure
9. Self-diagnosis
10. Operation and storage conditions
PXG4
Half duplex bit serial, Asynchronous com-
munication
even, none.
9600 bps, 19200 bps
Up to 32 units connectable including multi-
drop master function
Up to 500 m (total connect extension)
timer
-20 to 60˚C
90%RH MAX. (no condensing)
30 min MIN
1 to 50 A
0.1 A
0.1 A
0.0 to 50.0 A
Modbus-RTU
Data length 8 data bits. Parity ... Odd,
Program error supervision by watchdog
10 to 70 Hz, 9.8 m/s
49 m/s
Protect by non-volatile memory
-10 to 50˚C
2
(5 G) MAX.
2
(1 G) MAX.
(1) Mounting method:
(2) External terminals:
(3) Case:
(4) Protection structure:
(5) Dimensions: 48 (W)
(6) Mass:
• Controller:
• Instruction manual:
• Panel mounting frame: 1 pc
• Water-proof packing:
• Shunt resistor:
• Unit nameplate:
13.1 Program (ramp/soak) function
(1) Number of program steps:
(2) Control option:
(3) Basic function:
(4) Memory backup:
13.2 User functions
• Pressing the user key can perform Auto/Manual change,
13.3 Password function
• 3 level password function
11. Structure
12. Scope of delivery
13. User customize function
Standby ON/OFF change, remote SV change, ramp/soak
change or other function as assigned
• Panel front side: IP66, NEMA-4X equiva-
• Body: IP20 equivalent (slits on top and
• Terminals: IP00 equivalent. Terminal
16 steps
8 steps
4 steps
(1 step = 2 segments)
Control by digital input
Status output by digital output
[1] Segment time can be set in "Hour,
[2] Guarantee soak
[3] Repeat action
[4] PV start
[5] Delay start
[6] Power failure restoring function
EEPROM
Mounted with panel
Screw terminals, M3
• Material: ABS, and degeneration PPO
• Non-combustibility grade: UL94V-0
• Color: Black
About 200 g
equivalent
lent (if panel is mounted using our
genuine packing. Not water-proof if
mounted closely together.)
bottom)
cover can be mounted optionally.
Minutes" or "Minutes, Seconds"
1 unit
1 copy
1 pc
1 pc
1 pc
48 (H)
2 patterns, or
4 patterns
1 pattern,
80 (D) mm

Related parts for EDS11-158C