MAX11131AUI+ Maxim Integrated, MAX11131AUI+ Datasheet - Page 19

no-image

MAX11131AUI+

Manufacturer Part Number
MAX11131AUI+
Description
Analog to Digital Converters - ADC 12Bit 16 Ch 3Msps Serial ADC
Manufacturer
Maxim Integrated
Datasheet

Specifications of MAX11131AUI+

Rohs
yes
Number Of Channels
16
Architecture
SAR
Conversion Rate
3 MSPs
Resolution
12 bit
Input Type
Differential
Snr
72.3 dB
Interface Type
3-Wire Serial, Microwire, QSPI, SPI
Operating Supply Voltage
3 V
Maximum Operating Temperature
+ 125 C
Mounting Style
SMD/SMT
Package / Case
TSSOP-28
Maximum Power Dissipation
2162 mW
Minimum Operating Temperature
- 40 C
Number Of Converters
1
Voltage Reference
1 V
The MAX11129–MAX11132 produce a digital output that
corresponds to the analog input voltage as long as the
analog inputs are within the specified operating range.
Internal protection diodes confine the analog input volt-
age within the region of the analog power input rails
(V
from GND - 0.3V to V
device. Input voltages beyond GND - 0.3V and V
0.3V forward bias the internal protection diodes. Limit the
forward diode current to less than 50mA to avoid dam-
age to the MAX11129–MAX11132.
When writing to the ADC Configuration register, set
ECHO to 1 in ADC Configuration register to echo back
the configuration data onto DOUT at time n+1
Table
The MAX11129–MAX11132 feature nine scan modes
(Table
The next channel to be selected is identified in each SPI
frame. The conversion results are sent out in the next
frame. The manual mode works with the external clock
only. The FIFO is unused.
Repeat scanning channel N for number of times and
store all the conversion results in the FIFO. The number of
scans is programmed in the ADC Configuration register.
The repeat mode works with the internal clock only.
In Custom_Int and Custom_Ext modes, the device scans
preprogrammed channels in ascending order. The chan-
nels to be scanned in sequence are programmed in
the Custom Scan0 or Custom Scan1 registers. A new
Figure 8. Echo Back the Configuration Data
Maxim Integrated
DD
, GND) and allow the analog input voltage to swing
6).
3).
DD
DOUT
DIN
CS
Custom_Int and Custom_Ext
+ 0.3V without damaging the
3Msps, Low-Power, Serial 12-/10-Bit,
TURN ON ECHO
t = n-1
Analog Input
Scan Modes
Manual Mode
Repeat Mode
(Figure
ECHO
CONFIGURATION
DD
DATA
t = n
8,
+
I/P MUX is selected every frame on the thirteenth falling
edge of SCLK. Custom_Int works with the internal clock.
Custom_Ext works with the external clock.
In Standard_Int and Standard_Ext modes, the device
scans channels 0 through N in ascending order where
N is the last channel specified in the ADC Mode Control
register. A new I/P MUX is selected every frame on the
thirteenth falling edge of SCLK. Standard_Int works with
the internal clock. Standard_Ext works with the external
clock.
In Upper_Int and Upper_Ext modes, the device scans
channels N through 15/11/7/3 in ascending order where
N is the first channel specified in the ADC Mode Control
register. A new I/P MUX is selected every frame on the
thirteenth falling edge of SCLK. Upper_Int works with the
internal clock. Upper_Ext works with the external clock.
The SampleSet mode of operation allows the definition
of a unique channel sequence combination with maxi-
mum length of 256. SampleSet is supported only in the
external clock mode. SampleSet is ideally suited for mul-
tichannel measurement applications where some analog
inputs must be converted more often than others.
The SampleSet approach provides greater sequencing
flexibility for multichannel applications while alleviating
significant microcontroller or DSP (controlling unit) com-
munication overhead. SampleSet technology allows the
user to exploit available ADC input bandwidth without
need for constant communication between the ADC and
controlling unit. The user may define and load a unique
sequencing pattern into the ADC allowing both high- and
low-frequency inputs to be converted appropriately with-
out interface activity. With the unique sequence loaded
CONFIGURATION
CONFIGURATION
MAX11129–MAX11132
t = n+1
DATA
DATA
8-/16-Channel ADCs
CONFIGURATION
CONFIGURATION
t = n+2
DATA
DATA
Standard_Int and Standard_Ext
Upper_Int and Upper_Ext
SampleSet
19

Related parts for MAX11131AUI+