S9S08DZ60F2MLH Freescale Semiconductor, S9S08DZ60F2MLH Datasheet - Page 404

no-image

S9S08DZ60F2MLH

Manufacturer Part Number
S9S08DZ60F2MLH
Description
8-bit Microcontrollers - MCU M74K MASK ONLY-AUTO
Manufacturer
Freescale Semiconductor
Datasheet

Specifications of S9S08DZ60F2MLH

Rohs
yes
Core
HCS08
Processor Series
MC9S08DZ60
Data Bus Width
8 bit
Maximum Clock Frequency
40 MHz
Program Memory Size
60 KB
Data Ram Size
4 K
On-chip Adc
Yes
Operating Supply Voltage
2.7 V to 5.5 V
Operating Temperature Range
- 40 C to + 125 C
Package / Case
LQFP-64
Mounting Style
SMD/SMT

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
S9S08DZ60F2MLH
Manufacturer:
Freescale
Quantity:
274
Part Number:
S9S08DZ60F2MLH
Manufacturer:
FREESCALE
Quantity:
5 928
Part Number:
S9S08DZ60F2MLH
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
S9S08DZ60F2MLH
Manufacturer:
FREESCALE
Quantity:
5 928
Part Number:
S9S08DZ60F2MLH
Manufacturer:
QFP64
Quantity:
20 000
Part Number:
S9S08DZ60F2MLH
0
Company:
Part Number:
S9S08DZ60F2MLH
Quantity:
238
Part Number:
S9S08DZ60F2MLHR
Manufacturer:
FREESCALE
Quantity:
20 000
Appendix B Timer Pulse-Width Modulator (TPMV2)
at the transition from the value set in the modulus register and the next lower count value. This corresponds
to the end of a PWM period. (The 0x0000 count value corresponds to the center of a period.)
B.4.3
The meaning of channel interrupts depends on the current mode of the channel (input capture, output
compare, edge-aligned PWM, or center-aligned PWM).
When a channel is configured as an input capture channel, the ELSnB:ELSnA control bits select rising
edges, falling edges, any edge, or no edge (off) as the edge that triggers an input capture event. When the
selected edge is detected, the interrupt flag is set. The flag is cleared by the 2-step sequence described in
Section B.4.1, “Clearing Timer Interrupt
When a channel is configured as an output compare channel, the interrupt flag is set each time the main
timer counter matches the 16-bit value in the channel value register. The flag is cleared by the 2-step
sequence described in
B.4.4
For channels that are configured for PWM operation, there are two possibilities:
The flag is cleared by the 2-step sequence described in
404
When the channel is configured for edge-aligned PWM, the channel flag is set when the timer
counter matches the channel value register that marks the end of the active duty cycle period.
When the channel is configured for center-aligned PWM, the timer count matches the channel
value register twice during each PWM cycle. In this CPWM case, the channel flag is set at the start
and at the end of the active duty cycle, which are the times when the timer counter matches the
channel value register.
Channel Event Interrupt Description
PWM End-of-Duty-Cycle Events
Section B.4.1, “Clearing Timer Interrupt
MC9S08DZ60 Series Data Sheet, Rev. 4
Flags.”
Section B.4.1, “Clearing Timer Interrupt
Flags.”
Freescale Semiconductor
Flags.”

Related parts for S9S08DZ60F2MLH