MT48H16M16LFBF-75:H Micron Technology Inc, MT48H16M16LFBF-75:H Datasheet - Page 46

SDRAM 256M-BIT 1.8V 54-PIN VFBGA

MT48H16M16LFBF-75:H

Manufacturer Part Number
MT48H16M16LFBF-75:H
Description
SDRAM 256M-BIT 1.8V 54-PIN VFBGA
Manufacturer
Micron Technology Inc
Type
Mobile SDRAMr
Datasheet

Specifications of MT48H16M16LFBF-75:H

Format - Memory
RAM
Memory Type
Mobile SDRAM
Memory Size
256M (16Mx16)
Speed
132MHz
Interface
Parallel
Voltage - Supply
1.7 V ~ 1.95 V
Operating Temperature
0°C ~ 70°C
Package / Case
54-VFBGA
Organization
16Mx16
Density
256Mb
Address Bus
15b
Access Time (max)
8/6ns
Maximum Clock Rate
133MHz
Operating Supply Voltage (typ)
1.8V
Package Type
VFBGA
Operating Temp Range
0C to 70C
Operating Supply Voltage (max)
1.95V
Operating Supply Voltage (min)
1.7V
Supply Current
80mA
Pin Count
54
Mounting
Surface Mount
Operating Temperature Classification
Commercial
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
Q4707290

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MT48H16M16LFBF-75:H
Manufacturer:
MICRON
Quantity:
5 000
Part Number:
MT48H16M16LFBF-75:H
Manufacturer:
MICRON
Quantity:
5 520
Part Number:
MT48H16M16LFBF-75:H
Manufacturer:
Micron Technology Inc
Quantity:
10 000
Part Number:
MT48H16M16LFBF-75:H
Manufacturer:
MICRON/美光
Quantity:
20 000
Company:
Part Number:
MT48H16M16LFBF-75:H
Quantity:
260
Bank/Row Activation
Figure 16: Example: Meeting
PDF: 09005aef834c13d2
256mb_mobile_sdram_y36n.pdf - Rev. I 11/09 EN
Command
Before any READ or WRITE commands can be issued to a bank within the SDRAM, a
row in that bank must be opened. This is accomplished via the ACTIVE command,
which selects both the bank and the row to be activated.
After a row is opened with the ACTIVE command, a READ or WRITE command can be
issued to that row, subject to the
the clock period and rounded up to the next whole number to determine the earliest
clock edge after the ACTIVE command on which a READ or WRITE command can be
entered. For example, a
results in 2.5 clocks, rounded to 3. This is reflected in Figure 16 (page 46), which cov-
ers any case where 2 <
other specification limits from time units to clock cycles.)
A subsequent ACTIVE command to a different row in the same bank can only be issued
after the previous active row has been precharged. The minimum time interval between
successive ACTIVE commands to the same bank is defined by
A subsequent ACTIVE command to another bank can be issued while the first bank is
being accessed, which results in a reduction of total row-access overhead. The mini-
mum time interval between successive ACTIVE commands to different banks is defined
by
t
RRD.
CLK
t
RCD (MIN) When 2 <
ACTIVE
T0
t CK
256Mb: 16 Meg x 16, 8 Meg x 32 Mobile SDRAM
t
RCD (MIN)/
t
RCD specification of 20ns with a 125 MHz clock (8ns period)
NOP
t
RCD(MIN)
T1
46
t
RCD (MIN)/
t CK
t
RCD specification.
t
CK ≤ 3. (The same procedure is used to convert
NOP
Micron Technology, Inc. reserves the right to change products or specifications without notice.
T2
t
CK < 3
t CK
READ or
WRITE
t
RCD (MIN) should be divided by
Don’t Care
T3
Bank/Row Activation
©2008 Micron Technology, Inc. All rights reserved.
t
RC.

Related parts for MT48H16M16LFBF-75:H