Specifications of M28W320FCT70N6F

Format - Memory
FLASH
Memory Type
FLASH - Nor
Memory Size
32M (2M x 16)
Speed
70ns
Interface
Parallel
Voltage - Supply
2.7 V ~ 3.6 V
Operating Temperature
-40°C ~ 85°C
Package / Case
48-TSOP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M28W320FCT70N6F
Manufacturer:
STM
Quantity:
728
2
2.1
2.2
2.3
2.4
2.5
2.6
12/69
Signal descriptions
See
connected to this device.
Address inputs (A0-A20)
The Address Inputs select the cells in the memory array to access during Bus Read
operations. During Bus Write operations they control the commands sent to the Command
Interface of the internal state machine.
Data input/output (DQ0-DQ15)
The Data I/O outputs the data stored at the selected address during a Bus Read operation
or inputs a command or the data to be programmed during a Write Bus operation.
Chip Enable (E)
The Chip Enable input activates the memory control logic, input buffers, decoders and
sense amplifiers. When Chip Enable is at V
mode. When Chip Enable is at V
impedance and the power consumption is reduced to the stand-by level.
Output Enable (G)
The Output Enable controls data outputs during the Bus Read operation of the memory.
Write Enable (W)
The Write Enable controls the Bus Write operation of the memory’s Command Interface.
The data and address inputs are latched on the rising edge of Chip Enable, E, or Write
Enable, W, whichever occurs first.
Write Protect (WP)
Write Protect is an input that gives an additional hardware protection for each block. When
Write Protect is at V
cannot be changed. When Write Protect is at V
can be locked or unlocked. (refer to
Figure 1: Logic Diagram
IL
, the Lock-Down is enabled and the protection status of the block
and
IH
Table 1: Signal
the memory is deselected, the outputs are high
Table 7: Read Protection Register and Lock
IL
and Reset is at V
IH
, the Lock-Down is disabled and the block
Names, for a brief overview of the signals
IH
the device is in active
Register).