MT28F800B5WP-8 BET Micron Technology Inc, MT28F800B5WP-8 BET Datasheet - Page 13

IC FLASH 8MBIT 80NS 48TSOP

MT28F800B5WP-8 BET

Manufacturer Part Number
MT28F800B5WP-8 BET
Description
IC FLASH 8MBIT 80NS 48TSOP
Manufacturer
Micron Technology Inc
Datasheet

Specifications of MT28F800B5WP-8 BET

Format - Memory
FLASH
Memory Type
FLASH - Nor
Memory Size
8M (1M x 8 or 512K x 16)
Speed
80ns
Interface
Parallel
Voltage - Supply
4.5 V ~ 5.5 V
Operating Temperature
-40°C ~ 85°C
Package / Case
48-TSOP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
ERASE Sequence
block to logic 1. The command sequence necessary to
execute an ERASE is similar to that of a WRITE. To pro-
vide added security against accidental block erasure,
two consecutive command cycles are required to ini-
tiate an erase of a block. In the first cycle, addresses are
“Don’t Care,” and ERASE SETUP (20h) is given. In the
second cycle, V
within the block to be erased must be issued, and
ERASE CONFIRM (D0h) must be given. If a command
other than ERASE CONFIRM is given, the write and
erase status bits (SR4 and SR5) are set, and the device
is in the status register read mode.
starts the ERASE of the addressed block. Any READ
operation outputs the status register contents on
DQ0–DQ7. V
completed (SR7 = 1). When the ERASE is completed,
the device is in the status register read mode until
another command is issued. Erasing the boot block
also requires that either the RP# pin be set to V
the WP# pin be held HIGH at the same time V
to V
Table 4:
Notes: 1. SR3–SR5 must be cleared using CLEAR STATUS REGISTER.
09005aef8075d1ec
MT28F800B5_4.fm - Rev. 4, Pub. 2/2004
Executing an ERASE sequence sets all bits within a
After the ERASE CONFIRM (D0h) is issued, the ISM
SR5
PPH
0
0
0
0
1
1
1
1
.
STATUS BITS
PP
SR4
Status Register Error Decode
PP
must be held at V
0
0
1
1
0
0
1
1
must be brought to V
SR3
0
1
0
1
0
1
0
1
ERROR DESCRIPTION
No errors
V
WRITE error
WRITE error, V
ERASE error
ERASE error, V
Command sequencing error or WRITE/ERASE error
Command sequencing error, V
PPH
PP
voltage error
until the ERASE is
PPH
, an address
PP
PP
PP
voltage not valid at time of ERASE CONFIRM
voltage not valid at time of WRITE
HH
is set
SMART 5 BOOT BLOCK FLASH MEMORY
or
1
13
ERASE Suspension
ERASE is in progress is ERASE SUSPEND. This com-
mand allows other commands to be executed while
pausing the ERASE in progress. When the device has
reached the erase suspend mode, the erase suspend
status bit (SR6) and ISM status bit (SR7) is set. The
device may now be given a READ ARRAY, ERASE
RESUME or READ STATUS REGISTER command. After
READ ARRAY has been issued, any location not within
the block being erased may be read. If ERASE RESUME
is issued before SR6 has been set, the device immedi-
ately proceeds with the ERASE in progress.
ERROR HANDLING
(SR3), write (SR4) and erase (SR5) status bits may be
checked. If one or a combination of these three bits
has been set, an error has occurred. The ISM cannot
reset these three bits. To clear these bits, CLEAR STA-
TUS REGISTER (50h) must be given. If the VPP status
bit (SR3) is set, further write or erase operations can-
not resume until the status register is cleared. Table 4
lists the combination of errors
PP
The only command that may be issued while an
After the ISM status bit (SR7) has been set, the V
voltage error, with WRITE and ERASE errors
Micron Technology, Inc., reserves the right to change products or specifications without notice.
.
©2002 Micron Technology Inc.
8Mb
PP