BTS5234L Infineon Technologies, BTS5234L Datasheet - Page 21

no-image

BTS5234L

Manufacturer Part Number
BTS5234L
Description
IC HIGH SIDE PWR SWITCH PDSO-12
Manufacturer
Infineon Technologies
Series
PROFET®r
Type
High Sider
Datasheet

Specifications of BTS5234L

Package / Case
DSO-12
Input Type
Non-Inverting
Number Of Outputs
2
On-state Resistance
45 mOhm
Current - Output / Channel
3.5A
Current - Peak Output
28A
Voltage - Supply
4.5 V ~ 28 V
Operating Temperature
-40°C ~ 150°C
Mounting Type
Surface Mount
On Resistance (max)
0.045 Ohms
Maximum Operating Temperature
+ 150 C
Minimum Operating Temperature
- 40 C
Maximum Power Dissipation
1600 mW
Mounting Style
SMD/SMT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
DEMOBOARDPROFETIN - BOARD DEMO PROFET V2.0BTS
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
BTS5234LT
BTS5234LXT
SP000014704
SP000271656

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
BTS5234L
Manufacturer:
INFINEON
Quantity:
5 510
Part Number:
BTS5234L
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
For open load diagnosis in off state an external output pull-up resistor (
recommended. For calculation of the pull-up resistor, just the external leakage current
I
I
There is no internal leakage current from out to ground at BTS 5234L.
minimum supply voltage at which the open load diagnosis in off state must be ensured.
To reduce the stand-by current of the system, an open load resistor switch (
recommended.
4.3.3
The diagnosis signals have to be switched on by a high signal at sense enable pin (SEN).
See
Please note that the diagnosis is disabled, when no signal is provided at pin SEN.
Figure 17
The SEN pin circuit is designed equal to the input pin. Please refer to
The resistors
IS2 in case of reverse polarity and over voltage. Please refer to maximum ratings on
Page
The stand-by current of the BTS 5234L is minimized, when both input pins (IN1 and IN2)
and the sense enable pin (SEN) are on low level.
Data Sheet
leakage
leakage
Figure 17
SEN
8.
I
IS
and the open load threshold voltage
defines the leakage current in the complete system e.g. caused by humidity.
Sense Enable Function
t
sIS(SEN)
R
Timing of Sense Enable Signal
lim
for details on the timing between SEN pin and diagnosis signal
are recommended to limit the current through the sense pins IS1 and
t
dIS(SEN)
R
OL
=
V
---------------------------------------------------------- -
bb(min)
21
I
V
leakage
V
OUT(OL)
OUT(OL,max)
Smart High-Side Power Switch
t
sIS(SEN)
has to be taken into account.
t
dIS(SEN)
Figure 5
V1.0, 2004-01-23
V
BTS 5234L
bb(min)
t
t
for details.
R
S
OL
SEN.emf
OL
is the
) is
) is
I
IS
.

Related parts for BTS5234L