EVALSF2-ICE2A365 Infineon Technologies, EVALSF2-ICE2A365 Datasheet - Page 15

BOARD DEMO ICE2A365 40W SMPS

EVALSF2-ICE2A365

Manufacturer Part Number
EVALSF2-ICE2A365
Description
BOARD DEMO ICE2A365 40W SMPS
Manufacturer
Infineon Technologies
Series
CoolSET®F2r
Datasheets

Specifications of EVALSF2-ICE2A365

Main Purpose
AC/DC, Primary Side
Outputs And Type
1, Isolated
Power - Output
40W
Voltage - Output
16V
Current - Output
2.5A
Voltage - Input
85 ~ 270VAC
Regulator Topology
Flyback
Board Type
Fully Populated
Utilized Ic / Part
ICE2A365
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Frequency - Switching
-
Other names
EVALSF2-ICE2A365IN
Figure 20
3.8
An overload, open loop and overvoltage detection is
integrated within the Protection Unit. These three
failure modes are latched by an Error-Latch. Additional
thermal shutdown is latched by the Error-Latch. In case
of those failure modes the Error-Latch is set after a
blanking time of 5µs and the CoolMOS™ is shut down.
That blanking prevents the Error-Latch from distortions
caused by spikes during operation mode.
3.8.1
Figure 21 shows the Auto Restart Mode in case of
overload or open loop with normal load. The detection
of open loop or overload is provided by the Comparator
C3, C4 and the AND-gate G2 (see Figure 22). The
detection is activated by C4 when the voltage at pin
SoftS exceeds 5.3V. Till this time the IC operates in the
Soft-Start Phase. After this phase the comparator C3
can set the Error-Latch in case of open loop or overload
which leads the feedback voltage V
threshold of 4.8V. After latching VCC decreases till
8.5V and inactivates the IC. At this time the external
Soft-Start capacitor is discharged by the internal
transistor T1 due to Power Down Reset. When the IC
is inactive V
the Capacitor C
R
Reset and the external Soft-Start capacitor C
charged by the internal pull-up resistor R
the Soft-Start Phase which ends when the voltage at
pin SoftS exceeds 5.3V the detection of overload and
open loop by C3 and G2 is inactive. In this way the Start
Up Phase is not detected as an overload.
Version 2.6
Start-Up
5V
V
Gate
. Then the Error-Latch is reset by Power Up
Protection Unit (Auto Restart Mode)
Overload / Open Loop with Normal
Load
Internal Gate Rising Slope
VCC
ca. t = 130ns
increases till V
VCC
by means of the Start-Up Resistor
CCon
= 13.5V by charging
FB
to exceed the
Soft-Start
Soft-Start
. During
t
is
15
Figure 21
Figure 22
SoftS
FB
Driver
SoftS
VCC
13.5V
C
4.8V
5.3V
8.5V
FB
Soft-Start
6.5V
Overload / Open Loop with Normal Load
R
T1
5µs Blanking
Auto Restart Mode
FB-Detection
Soft-Start
R
6.5V
FB
Detection
Failure
Soft-Start Phase
4.8V
5.3V
Power Up Reset
Functional Description
T
C4
C3
Burst1
CoolSET™-F2
T
Restart
G2
25 Dec 2006
Error-Latch
t
t
t
t

Related parts for EVALSF2-ICE2A365