LPC2478FBD208,551 NXP Semiconductors, LPC2478FBD208,551 Datasheet - Page 235

IC ARM7 MCU 512K LCD 208-LQFP

LPC2478FBD208,551

Manufacturer Part Number
LPC2478FBD208,551
Description
IC ARM7 MCU 512K LCD 208-LQFP
Manufacturer
NXP Semiconductors
Series
LPC2400r
Datasheets

Specifications of LPC2478FBD208,551

Program Memory Type
FLASH
Program Memory Size
512KB (512K x 8)
Package / Case
208-LQFP
Core Processor
ARM7
Core Size
16/32-Bit
Speed
72MHz
Connectivity
CAN, EBI/EMI, Ethernet, I²C, Microwire, MMC, SPI, SSI, SSP, UART/USART, USB OTG
Peripherals
Brown-out Detect/Reset, DMA, I²S, LCD, POR, PWM, WDT
Number Of I /o
160
Ram Size
96K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 3.6 V
Data Converters
A/D 8x10b; D/A 1x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Processor Series
LPC24
Core
ARM7TDMI-S
Data Bus Width
16 bit, 32 bit
Data Ram Size
98 KB
Interface Type
CAN/I2C/I2S/IrDA/SPI/SSP/UART/USB
Maximum Clock Frequency
72 MHz
Number Of Programmable I/os
160
Number Of Timers
4
Operating Supply Voltage
3.3 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
3rd Party Development Tools
MDK-ARM, RL-ARM, ULINK2, DK-35TS-LPC2478, DK-57TS-LPC2478, DK-57VTS-LPC2478, SOMDIMM-LPC2478, SAB-TFBGA208, KSK-LPC2478-JL, MCB2470
Development Tools By Supplier
OM11015, OM11019, OM11022
Minimum Operating Temperature
- 40 C
On-chip Adc
8-ch x 10-bit
On-chip Dac
1-ch x 10-bit
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
622-1034 - PROGRAMMERS, DEVELOPMENT SYSTEMS622-1033 - KIT LCD TOUCH 5.7" FOR LPC2478MCB2470 - BOARD EVAL NXP LPC247X SERIESOM11022 - EVAL LPC-STICK WITH LPC2478OM11019 - BOARD EVAL FOR LPC2478568-4742 - MODULE DIMM LPC2478 ARM7568-4741 - KIT LCD TOUCH 5.7" FOR LPC2478622-1028 - KIT LCD TOUCH 5.7" FOR LPC2478KSDKLPC2478-PL - KIT IAR KICKSTART NXP LPC2478622-1024 - BOARD SCKT ADAPTER FOR TFBGA208568-4369 - BOARD EVAL FOR LPC2478622-1005 - USB IN-CIRCUIT PROG ARM7 LPC2K
Eeprom Size
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
568-4363
935284069551
LPC2478FBD208-S

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LPC2478FBD208,551
Quantity:
9 999
Part Number:
LPC2478FBD208,551
Manufacturer:
NXP Semiconductors
Quantity:
10 000
Part Number:
LPC2478FBD208,551
Manufacturer:
NXP/恩智浦
Quantity:
20 000
NXP Semiconductors
UM10237_4
User manual
7.2.16 Flow Control Counter Register (FlowControlCounter - 0xFFE0 0170)
Table 11–220
Table 220. Receive Status Vector register (RSV - address 0xFFE0 0160) bit description
[1]
The Flow Control Counter register (FlowControlCounter) has an address of 0xFFE0 0170.
Table 11–221
Bit
15:0
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
The EMAC doesn't distinguish the frame type and frame length, so, e.g. when the IP(0x8000) or
ARP(0x0806) packets are received, it compares the frame type with the max length and gives the "Length
out of range" error. In fact, this bit is not an error indication, but simply a statement by the chip regarding the
status of the received frame.
Symbol
Received byte count
Packet previously
ignored
RXDV event
previously seen
Carrier event
previously seen
Receive code
violation
CRC error
Length check error
Length out of range
Receive OK
Multicast
Broadcast
Dribble Nibble
Control frame
PAUSE
Unsupported Opcode The current frame was recognized as a Control Frame but
VLAN
-
lists the bit definitions of the RSV register.
lists the bit definitions of the register.
Rev. 04 — 26 August 2009
[1]
Function
Indicates length of received frame.
Indicates that a packet was dropped.
Indicates that the last receive event seen was not long
enough to be a valid packet.
Indicates that at some time since the last receive statistics,
a carrier event was detected.
Indicates that MII data does not represent a valid receive
code.
The attached CRC in the packet did not match the
internally generated CRC.
Indicates the frame length field does not match the actual
number of data items and is not a type field.
Indicates that frame type/length field was larger than
1518 bytes.
The packet had valid CRC and no symbol errors.
The packet destination was a multicast address.
The packet destination was a broadcast address.
Indicates that after the end of packet another 1-7 bits were
received. A single nibble, called dribble nibble, is formed
but not sent out.
The frame was a control frame.
The frame was a control frame with a valid PAUSE
opcode.
contains an unknown opcode.
Frame’s length/type field contained 0x8100 which is the
VLAN protocol identifier.
Unused
Chapter 11: LPC24XX Ethernet
UM10237
© NXP B.V. 2009. All rights reserved.
235 of 792
0
0
0
0
Reset
value
0x0
0
0
0
0
0
0
0
0
0
0
0
0x0

Related parts for LPC2478FBD208,551