Z8F0813HJ005EG Zilog, Z8F0813HJ005EG Datasheet - Page 79

IC Z8 ENCORE MCU FLASH 8K 28SSOP

Z8F0813HJ005EG

Manufacturer Part Number
Z8F0813HJ005EG
Description
IC Z8 ENCORE MCU FLASH 8K 28SSOP
Manufacturer
Zilog
Series
Encore!® XP®r
Datasheet

Specifications of Z8F0813HJ005EG

Core Processor
Z8
Core Size
8-Bit
Speed
5MHz
Connectivity
IrDA, UART/USART
Peripherals
Brown-out Detect/Reset, LED, POR, PWM, WDT
Number Of I /o
24
Program Memory Size
8KB (8K x 8)
Program Memory Type
FLASH
Ram Size
1K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 3.6 V
Oscillator Type
Internal
Operating Temperature
-40°C ~ 105°C
Package / Case
28-SSOP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Data Converters
-
Other names
269-4182
Z8F0813HJ005EG
PS025203-0405
it is appropriate to have the Timer Output make a state change at a One-Shot time-out
(rather than a single cycle pulse), first set the TPOL bit in the Timer Control Register to
the start value before enabling ONE-SHOT mode. After starting the timer, set TPOL to the
opposite bit value.
The steps for configuring a timer for ONE-SHOT mode and initiating the count are as fol-
lows:
1. Write to the Timer Control register to:
2. Write to the Timer High and Low Byte registers to set the starting count value.
3. Write to the Timer Reload High and Low Byte registers to set the Reload value.
4. If appropriate, enable the timer interrupt and set the timer interrupt priority by writing
5. If using the Timer Output function, configure the associated GPIO port pin for the
6. Write to the Timer Control register to enable the timer and initiate counting.
In ONE-SHOT mode, the system clock always provides the timer input. The timer period
is given by the following equation:
CONTINUOUS Mode
In CONTINUOUS mode, the timer counts up to the 16-bit Reload value stored in the
Timer Reload High and Low Byte registers. The timer input is the system clock. Upon
reaching the Reload value, the timer generates an interrupt, the count value in the Timer
High and Low Byte registers is reset to
Output alternate function is enabled, the Timer Output pin changes state (from Low to
High or from High to Low) at timer Reload.
The steps for configuring a timer for CONTINUOUS mode and initiating the count are as
follows:
1. Write to the Timer Control register to:
One-Shot Mode Time-Out Period (s)
to the relevant interrupt registers.
Timer Output alternate function.
Disable the timer
Configure the timer for ONE-SHOT mode.
Set the prescale value.
Set the initial output level (High or Low) if using the Timer Output alternate
function.
Disable the timer
Configure the timer for CONTINUOUS mode.
Set the prescale value.
P R E L I M I N A R Y
0001H
=
(
------------------------------------------------------------------------------------------------ -
Reload Value Start Value
and counting resumes. Also, if the Timer
System Clock Frequency (Hz)
Z8 Encore!
Product Specification
®
Z8F0823 Series
)
×
Prescale
Timers
62