AT90LS4433-4AC Atmel, AT90LS4433-4AC Datasheet - Page 119

IC MCU 4K 4MHZ A/D LV 32TQFP

AT90LS4433-4AC

Manufacturer Part Number
AT90LS4433-4AC
Description
IC MCU 4K 4MHZ A/D LV 32TQFP
Manufacturer
Atmel
Series
AVR® 90LSr
Datasheet

Specifications of AT90LS4433-4AC

Core Processor
AVR
Core Size
8-Bit
Speed
4MHz
Connectivity
SPI, UART/USART
Peripherals
Brown-out Detect/Reset, POR, PWM, WDT
Number Of I /o
20
Program Memory Size
4KB (2K x 16)
Program Memory Type
FLASH
Eeprom Size
256 x 8
Ram Size
128 x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 6 V
Data Converters
A/D 6x10b
Oscillator Type
External
Operating Temperature
0°C ~ 70°C
Package / Case
32-TQFP, 32-VQFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT90LS4433-4AC
Manufacturer:
ATM
Quantity:
72
Errata for
AT90S/LS4433 Rev.
Rev. C/D/E/F
1042H–AVR–04/03
7. BOD Keeps the Device in Reset at Low Temperature
6. Fuses and Programming Mode
5. Incorrect Channel Change in Free Running Mode
4. Bandgap Reference Stabilizing Time
BOD Keeps the Device in Reset at Low Temperature
Fuses and Programming Mode
Incorrect Channel Change in Free Running Mode
Bandgap Reference Stabilizing Time
Brown-out Detection Level
Serial Programming at Voltages below 2.9V
UART Loses Synchronization if RXD Line is Low when UART Receive is Disabled
When the device operates at low temperature (below 0°C) and the BOD is enabled,
tha part may fail to start up. AT low temperature the BOD may never release the
reset, and the part will not start the application. The problem will only occur during
start-up and an already running application wil not go into reset even if the
temperature goes below 0°C.
Note that this also affects the described workaround for Errata no. 4.
Problem Fix/Workaround
If the device operates at low temperature and a BOD is required, an external BOD
c i r c u i t m u s t b e u s e d . A l t e r n a t i v e l y , A T m e g a 8 c a n b e u s e d i n s te a d o f
AT90S/LS4433.
After programming the Fuses in Serial Programming mode, it is not possible to pro-
gram the Flash or EEPROM. If leaving Programming mode, it is not possible to re-
enter Programming mode.
Problem Fix/Workaround
Power the part down and backup again after programming the Fuses or leaving Pro-
gramming mode.
If the ADC operates in Free Running mode and channels are changed by writing to
ADMUX, shortly after the ADC Interrupt Flag (ADIF in ADCSR) is set, the new set-
ting in ADMUX may affect the ongoing conversion.
Problem Fix/Workaround
Use Single Conversion mode when scanning channels, or avoid changing ADMUX
util at least 0.5 ADC clock cycles after ADIF goes high.
The time for the internal voltage reference for the Analog Comparator to stabilize is
longer than specified. The stabilizing period starts after the bandgap reference has
been selected, and can go on for as much as 10 seconds.
Problem Fix/Workaround
The Bandgap reference will be stable immediately if the internal Brown-out Detector
is enabled.