MAX16031ETM+ Maxim Integrated Products, MAX16031ETM+ Datasheet - Page 29

IC SYSTEM MON EEPROM 48-TQFN

MAX16031ETM+

Manufacturer Part Number
MAX16031ETM+
Description
IC SYSTEM MON EEPROM 48-TQFN
Manufacturer
Maxim Integrated Products
Type
Multi-Voltage Supervisorr
Datasheet

Specifications of MAX16031ETM+

Number Of Voltages Monitored
8
Output
Open Drain or Open Collector
Reset
Active Low
Reset Timeout
Adjustable/Selectable
Voltage - Threshold
8 Selectable Threshold Combinations
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
48-TQFN Exposed Pad
Manual Reset
Resettable
Watchdog
No Watchdog
Supply Voltage (max)
14 V
Supply Voltage (min)
2.9 V
Supply Current (typ)
3000 uA
Maximum Power Dissipation
2222.2 mW
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Minimum Operating Temperature
- 40 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Table 10. Fault Masks
REGISTER
ADDRESS
54h
55h
56h
57h
ADDRESS
MEMORY
EEPROM
______________________________________________________________________________________
D4h
D5h
D6h
D7h
RANGE
[7:4]
BIT
[0]
[1]
[2]
[3]
[0]
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[0]
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[0]
[1]
[2]
[3]
[4]
[5]
[6]
[7]
EEPROM-Based System Monitors
1 = Short-circuit detection at remote temperature sensor 1 is masked.
1 = Open-circuit detection at remote temperature sensor 1 is masked.
1 = Short-circuit detection at remote temperature sensor 2 is masked.
1 = Open-circuit detection at remote temperature sensor 2 is masked.
Not used.
1 = IN1 primary overvoltage and undervoltage faults are masked.
1 = IN2 primary overvoltage and undervoltage faults are masked.
1 = IN3 primary overvoltage and undervoltage faults are masked.
1 = IN4 primary overvoltage and undervoltage faults are masked.
1 = IN5 primary overvoltage and undervoltage faults are masked.
1 = IN6 primary overvoltage and undervoltage faults are masked.
1 = IN7 primary overvoltage and undervoltage faults are masked.
1 = IN8 primary overvoltage and undervoltage faults are masked.
1 = IN1 secondary overvoltage and undervoltage faults are masked.
1 = IN2 secondary overvoltage and undervoltage faults are masked.
1 = IN3 secondary overvoltage and undervoltage faults are masked.
1 = IN4 secondary overvoltage and undervoltage faults are masked.
1 = IN5 secondary overvoltage and undervoltage faults are masked.
1 = IN6 secondary overvoltage and undervoltage faults are masked.
1 = IN7 secondary overvoltage and undervoltage faults are masked.
1 = IN1 secondary overvoltage and undervoltage faults are masked.
1 = Internal temperature sensor primary overtemperature fault masked.
1 = Remote temperature sensor 1 primary overtemperature fault masked.
1 = Remote temperature sensor 2 primary overtemperature fault masked.
1 = Internal temperature sensor secondary overtemperature fault masked.
1 = Remote temperature sensor 1 secondary overtemperature fault masked.
1 = Remote temperature sensor 2 secondary overtemperature fault masked.
1 = Current-sense primary overcurrent fault masked.
1 = Current-sense secondary overcurrent fault masked.
with Nonvolatile Fault Memory
DESCRIPTION
29

Related parts for MAX16031ETM+