DVK-BTM411 Laird Technologies, DVK-BTM411 Datasheet - Page 16

BLUETOOTH EVAL BOARD BTM411

DVK-BTM411

Manufacturer Part Number
DVK-BTM411
Description
BLUETOOTH EVAL BOARD BTM411
Manufacturer
Laird Technologies
Type
Transceiverr
Datasheets

Specifications of DVK-BTM411

Frequency
2.4GHz
Wireless Frequency
2.402 GHz to 2.48 GHz
Interface Type
UART
Data Rate
2.1 Mbps
Operating Voltage
3 V to 3.3 V
Antenna
Multilayer Ceramic Integrated
Operating Temperature Range
- 30 C to + 70 C
Output Power
4 dBm
Technology/ Type
Development Kit
For Use With/related Products
BTM411
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
DVK-BTM411

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DVK-BTM411-02
Manufacturer:
LAIRD
Quantity:
2
BTM410/411
Bluetooth
AT COMMAND SET
REFERENCE
16 www.lairdtech.com
®
AT Data Module
3. ATSn=?
4. AT&Fn
5. AT&F*
6. AT&F+
7. AT&W
This will return the valid range of values for register n.
For recognized values of n
Response: <cr,lf>Sn:(nnnn..mmmm)<cr,lf>OK<cr,lf>
For unrecognized values of n
Response: <cr,lf>ERROR nn<cr,lf>
This command will only work when the device is in local command and unconnected mode.
Depending on the value of ‘n’ it installs S Register values appropriate for various power modes,
ranging from minimum power consumption to maximum.
Legal values of ‘n’ are as per the following table. All other values of n will generate a syntax error
response. If ‘n’ is not specified then a default value of 0 is assumed where the baud rate is
NOT changed.
The new values are NOT updated in non-volatile memory until the AT&W command is sent to
the device.
Response: <cr,lf>OK<cr,lf>
Or
Response: <cr,lf>ERROR nn<cr,lf>
The AT&F* variant of the command installs values in S registers as per command AT&F4 and then
all other user parameters in non-volatile memory are erased. This means that the trusted device
database is cleared, and so are parameters related to the following commands: AT+BTR, AT+BTN,
AT+BTS.
Response: <cr,lf>OK<cr,lf>
Or
Response: <cr,lf>ERROR nn<cr,lf>
This command erases all user parameters in non-volatile memory except S Registers 520 to 525.
This means that the trusted device database is cleared, and so are parameters related to the following
commands: AT+BTR, AT+BTN, AT+BTS.
Response: <cr,lf>OK<cr,lf>
Or
Response: <cr,lf>ERROR nn<cr,lf>
Writes current S Register values to non-volatile memory so that they are retained over a power cycle.
Response: <cr,lf>OK<cr,lf>
Or
Response: <cr,lf>ERROR nn<cr,lf>
&F0 (Default)
&F1
&F2
&F3
&F4
&F5
{Read S Register – Valid Range}
{Set S Register Defaults}
{Clear Non-volatile Memory}
{Clear Non-volatile Memory}
{Write S Registers to Non-volatile Memory}
Medium power consumption, UART baud rate unchanged
Minimum power consumption, UART baud rate set to 9600
Minimum power consumption, UART baud rate set to 38400
Minimum power consumption, UART baud rate set to 115200
Medium power consumption, UART baud rate set to 115200
Maximum power consumption, UART baud rate set to 115200
Laird Technologies