STEVAL-IHP001V3 STMicroelectronics, STEVAL-IHP001V3 Datasheet - Page 10

BOARD SMART PLUG STM32 SPZB260PR

STEVAL-IHP001V3

Manufacturer Part Number
STEVAL-IHP001V3
Description
BOARD SMART PLUG STM32 SPZB260PR
Manufacturer
STMicroelectronics
Series
Zigbee™ SmartPlugr
Type
Microcontroller, Energy Meteringr
Datasheets

Specifications of STEVAL-IHP001V3

Frequency
2.4GHz
For Use With/related Products
STM32F10x, SPZB260-PRO, STPM01
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
497-10677
Functions
Table 6.
10/60
Symbol
ZCR
BFR
AW
RW
SW
LIN
BIT
MA
MB
BIL
Zero crossing signal
Active energy
Reactive energy
Apparent energy
Line frequency signal
Base frequency range
Stepper motor signals
Tamper flag
No load condition
Internal signal description
Name
Provides positive pulse every time the line voltage crosses zero
Pulse frequency signal proportional to active energy
Pulse frequency signal proportional to reactive energy
Pulse frequency signal proportional to apparent energy
This signal is high when the voltage channel value is rising and it is low when
the voltage channel is falling. Basically this signal is the sign of dv/dt.
This signal is high when either the voltage line frequency is outside the
nominal band or the voltage register is below 64.
It is cleared when the voltage line frequency is inside the nominal band and
the voltage register goes above 128.
Signal available in MOP and MON to drive a stepper motor
This signal provides the information on the tamper status. If low no tamper is
detected, when high a tamper condition has been detected. This signal is part
of the status register but is also available on the SDATD pin when in
standalone mode.
Provides information on the load condition. This signal is part of the status
register but is also available on the SCLNLC pin when in standalone mode.
BIL=1 no load condition, BIL=0 normal operation.
Doc ID 10853 Rev 7
Description
STPM01

Related parts for STEVAL-IHP001V3