MTCBA-C1-N16 Multi-Tech Systems, MTCBA-C1-N16 Datasheet - Page 127

no-image

MTCBA-C1-N16

Manufacturer Part Number
MTCBA-C1-N16
Description
MODEM ETHERNET
Manufacturer
Multi-Tech Systems
Datasheets

Specifications of MTCBA-C1-N16

Function
Transceiver, CDMA, Modem
Modulation Or Protocol
CDMA2000
Frequency
800MHz, 1.9GHz
Applications
Aeris Networks (USA)
Interface
RS-232
Data Rate - Maximum
153.6 kbps
Voltage - Supply
9 V ~ 32 V
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
Q4976016

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MTCBA-C1-N16
Manufacturer:
Multi-Tech Systems
Quantity:
135
Multi-Tech Systems, Inc. CDMA C1 AT Commands Reference Guide (PN S000478C)
Command Name Saved Directly
+WSMO
+WSPS
+WSOS
+WSPC
+WSRA
+WTBMPRS
+WTUOOS
+WUSLMSK
+WWAKE
A
D
E
H
I
L
M
S0
S10
S11
S3
S4
S5
S6
S7
S8
S9
T
Z
to NV
No
No
Yes
Yes
Yes
Yes
Yes
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
Saved to NV
with &W
No
No
Yes
Yes
Yes
Yes
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
Affected by Z
Yes (Set to C,2)
No
No
No
Yes (Set to NV)
Yes (Set to NV)
Yes (Set to NV)
Yes (Set to NV)
No
No
No
Yes (Set to 1)
No
No
Yes (Set to 0)
Yes (Set to 0)
Yes (Set to 0)
Yes (Set to 14)
Yes (Set to 95)
Yes (Set to 13)
Yes (Set to 10)
Yes (Set to 8)
Yes (Set to 2)
Yes (Set to 50)
Yes (Set to 2)
Yes (Set to 6)
No
No
Chapter 21 – Effects of AT&W, ATZ, and AT&F
Affected by &F
Yes (Set to C,2)
No
No
No
Yes (Set to 0)
Yes (Set to 3)
Yes (Set to 4,36)
Yes (Set to
FFFFDFF6,0)
No
No
No
Yes (Set to 1)
No
No
Yes (Set to 0)
Yes (Set to 0)
Yes (Set to 0)
Yes (Set to 14)
Yes (Set to 95)
Yes (Set to 13)
Yes (Set to 10)
Yes (Set to 8)
Yes (Set to 2)
Yes (Set to 50)
Yes (Set to 2)
Yes (Set to 6)
No
No
Listed
by &V
Yes
No
No
No
Yes
Yes
Yes
Yes
No
No
No
Yes
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
127