AT86RF212-ZU Atmel, AT86RF212-ZU Datasheet - Page 86

IC TXRX ZIGBE/802.15.4/ISM 32QFN

AT86RF212-ZU

Manufacturer Part Number
AT86RF212-ZU
Description
IC TXRX ZIGBE/802.15.4/ISM 32QFN
Manufacturer
Atmel
Datasheet

Specifications of AT86RF212-ZU

Frequency
700MHz, 800MHz, 900MHz
Data Rate - Maximum
250kbps
Modulation Or Protocol
802.15.4 Zigbee, 6LoWPAN, ISM
Applications
ISM, ZigBee™
Power - Output
10dBm
Sensitivity
-110dBm
Voltage - Supply
1.8 V ~ 3.6 V
Current - Receiving
9.2mA
Current - Transmitting
25mA
Data Interface
PCB, Surface Mount
Antenna Connector
PCB, Surface Mount
Operating Temperature
-40°C ~ 85°C
Package / Case
32-VQFN Exposed Pad, 32-HVQFN, 32-SQFN, 32-DHVQFN
Number Of Receivers
1
Number Of Transmitters
1
Wireless Frequency
769 MHz to 935 MHz
Interface Type
SPI
Noise Figure
7 dB
Output Power
21 dB
Operating Supply Voltage
1.8 V, 3 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Maximum Supply Current
25 mA
Minimum Operating Temperature
- 40 C
Modulation
OQPSK
Protocol Supported
802.15.4
Operating Temperature (min)
-40C
Operating Temperature (max)
85C
Operating Temperature Classification
Industrial
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Memory Size
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT86RF212-ZU
Manufacturer:
HITTITE
Quantity:
5 000
Part Number:
AT86RF212-ZU
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
AT86RF212-ZUR
Manufacturer:
MICROCHIP/微芯
Quantity:
20 000
6.6.6 Register Description
86
AT86RF212
Table 6-29. CCA Measurement Period and Access in BUSY_RX State
It is recommended to perform CCA measurements in RX_ON state only. To avoid
switching accidentally to BUSY_RX state, the SHR detection can be disabled by setting
register bit RX_PDT_DIS (register 0x15, RX_SYN), refer to section 7.2.3. The receiver
remains in RX_ON state to perform a CCA measurement until the register bit
RX_PDT_DIS is set back to continue the frame reception. In this case, the CCA
measurement duration is 8 symbol periods.
Register 0x01 (TRX_STATUS):
Two register bits of register 0x01 (TRX_STATUS) indicate the status of the CCA
measurement.
Table 6-30. Register 0x01 (TRX_STATUS)
• Bit 7 – CCA_DONE
This register indicates completion a CCA measurement, which is additionally indicated
by the interrupt IRQ_4 (CCA_ED_DONE). Note that register bit CCA_DONE is cleared
in response to a CCA_REQUEST.
Bit
Name
Read/Write
Reset Value
Bit
Name
Read/Write
Reset Value
Note:
CCA Mode
1
2
3
0
1. After detecting the SHR, an automated ED measurement is started with a length of
8 symbol periods (2 symbol periods for high rate PHY modes). This automated ED
measurement must be finished to provide a result for the CCA measurement. Only
one automated ED measurement per frame is performed.
7
CCA_DONE
R
0
3
TRX_STATUS[3]
R
0
Request within ED Measurement
Energy above threshold
CCA result is available after finishing
automated ED measurement period.
Carrier sense only
CCA result is immediately available after request.
Carrier sense with energy above threshold (AND)
CCA result is available after finishing
automated ED measurement period.
Carrier sense with energy above threshold (OR)
CCA result is available after finishing
automated ED measurement period.
6
CCA_STATUS
R
0
2
TRX_STATUS[2]
R
0
(1)
5
Reserved
R
0
1
TRX_STATUS[1]
R
0
Request after ED Measurement
CCA result is immediately available
after request.
CCA result is immediately available
after request.
CCA result is immediately available
after request.
8168C-MCU Wireless-02/10
4
TRX_STATUS[4]
R
0
0
TRX_STATUS[0]
R
0