Number Of Adc Inputs
2
Number Of Dac Outputs
2
Conversion Rate
48 KSPS
Interface Type
Serial (2-Wire, 3-Wire, 4-Wire)
Resolution
12 bit
Operating Supply Voltage
3.7 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Package / Case
BGA
Minimum Operating Temperature
- 25 C
Number Of Channels
2 ADC/2 DAC
Supply Current
260 uA
Thd Plus Noise
- 83 dB
Audio Codec Type
Stereo
No. Of Adcs
2
No. Of Dacs
2
No. Of Input Channels
8
No. Of Output Channels
6
Adc / Dac Resolution
24bit
Adcs / Dacs Signal To Noise Ratio
95dB
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Production Data
Register 15h Alarm Hours/Day
Register 16h Alarm Date/Month
w
REGISTER
REGISTER
REGISTER
ADDRESS
ADDRESS
ADDRESS
Date/Month
Hours/Day
RTC Time
R21 (15h)
R22 (16h)
R23 (17h)
Control
Alarm
Alarm
BIT
BIT
BIT
11:8
12:8
4:0
5:0
15
14
11
10
5
9
8
RTC_ALMDATE[5:0]
RTC_ALMDAY[3:0]
RTC_ALMHRS[4:0]
RTC_ALMMTH[4:0]
RTC_ALMSET
RTC_ALMSTS
RTC_ALMHPM
RTC_12HR
RTC_BCD
RTC_SET
RTC_STS
LABEL
LABEL
LABEL
DEFAULT
DEFAULT
DEFAULT
0_0000
0
0
0
0
1
1
00_0000
0_0000
0000
0
RTC Coding (applies to all time registers)
0 = Binary
1 = BCD
RTC 12/24 hours mode
1 = 12 hours (MSB of RTC_HRS indicates AM/PM)
0 = 24 hours (MSB of RTC_HRS is 0)
Stops RTC seconds counter (instruction only)
0 = normal operation
1 = stop counter
Status of RTC seconds counter
0 = normal operation
1 = counter stopped
Stops alarms (instruction only)
0 = normal operation
1 = stop alarms
It is recommended to stop alarms when setting the
RTC alarm. This avoids false alarms.
Actual status of ALARM circuitry
0 = normal operation
1 = alarms stopped
Day alarm register, with range 1-7, 1 = Sunday.
All 1's sets to 'don't care' state.
Note, during programming it is best to disable the
Alarm Enable request bit to avoid false alarms.
Alarm hours AM/PM flag
0 = AM
1 = PM
Only applicable in 12 hour mode. In 24 hour mode
set to 1 if RTC_ALMHRS is set to all 1’s ‘don’t
care’ or 0 otherwise.
Hours alarm register with range 0-23 in 24 hours
mode and 1-12 in 12 hour. In 12 hour mode bit 5 is
used as PM/not-AM flag. All 1's sets to 'don't care'
state.
Note, during programming it is best to disable the
Alarm Enable request bit to avoid false alarms.
Month alarm register with range 1-12. All 1's sets
to 'don't care' state.
Note, during programming it is best to disable the
Alarm Enable request bit to avoid false alarms.
Date alarm register with range 1-31. All 1's sets to
'don't care' state.
Note, during programming it is best to disable the
Alarm Enable request bit to avoid false alarms.