L6470H STMicroelectronics, L6470H Datasheet - Page 22

Motor / Motion / Ignition Controllers & Drivers 8 - 45V 7.0A 1/128 Microstepping SPI

L6470H

Manufacturer Part Number
L6470H
Description
Motor / Motion / Ignition Controllers & Drivers 8 - 45V 7.0A 1/128 Microstepping SPI
Manufacturer
STMicroelectronics
Type
Micro Stepping Motor Driverr
Series
-r
Datasheet

Specifications of L6470H

Product
Stepper Motor Controllers / Drivers
Operating Supply Voltage
8 V to 45 V
Supply Current
0.5 mA
Mounting Style
SMD/SMT
Package / Case
HTSSOP-28
Operating Temperature
- 40 C to + 125 C
Applications
Stepper Motor Driver, 2 Phase
Evaluation Tools
*
Number Of Outputs
1
Current - Output
3A
Voltage - Load
8 V ~ 45 V
Voltage - Supply
3.3V, 5V
Mounting Type
*
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
L6470H
Manufacturer:
STMicroelectronics
Quantity:
135
Part Number:
L6470H
Manufacturer:
ST
0
Part Number:
L6470H
Manufacturer:
ST
Quantity:
20 000
Part Number:
L6470H
0
Company:
Part Number:
L6470H
Quantity:
50
Company:
Part Number:
L6470H
Quantity:
50
Part Number:
L6470HTR
Manufacturer:
ST
0
Part Number:
L6470HTR
Manufacturer:
ST
Quantity:
20 000
Part Number:
L6470HTR
0
Company:
Part Number:
L6470HTR
Quantity:
9 000
Functional description
6.7
6.7.1
6.7.2
22/64
Motor control commands
The L6470 can accept different types of commands:
For detailed command descriptions refer to
Constant speed commands
A constant speed command produces a motion in order to reach and maintain a user-
defined target speed starting from the programmed minimum speed (set in MIN_SPEED
register) and with the programmed acceleration/deceleration value (set in ACC and DEC
registers). A new constant speed command can be requested anytime.
Figure 7.
Positioning commands
An absolute positioning command produces a motion in order to reach a user-defined
position that is sent to the device together with the command. The position can be reached
performing the minimum path (minimum physical distance) or forcing a direction (see
Figure
Performed motor motion is compliant to programmed speed profile boundaries
(acceleration, deceleration, minimum and maximum speed).
Note that with some speed profiles or positioning commands, the deceleration phase can
start before the maximum speed is reached.
constant speed commands (Run, GoUntil, ReleaseSW),
absolute positioning commands (GoTo, GoTo_DIR, GoHome, GoMark),
motion commands (Move),
stop commands (SoftStop, HardStop, SoftHiz, HardHiz).