LIS3LV02DL STMicroelectronics, LIS3LV02DL Datasheet - Page 39
LIS3LV02DL
Manufacturer Part Number
LIS3LV02DL
Description
Board Mount Accelerometers MEMS INERTIAL SENSOR
Manufacturer
STMicroelectronics
Datasheet
1.LIS3LV02DL.pdf
(48 pages)
Specifications of LIS3LV02DL
Sensing Axis
X, Y, Z
Acceleration
2 g, 6 g
Digital Output - Number Of Bits
12 bit, 16 bit
Supply Voltage (max)
3.6 V
Supply Voltage (min)
2.16 V
Supply Current
0.65 mA
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Digital Output - Bus Interface
I2C, SPI
Sensitivity
1024 LSB/g
Package / Case
LGA-16
Output Type
Digital
Acceleration Range
±2g, ±6g
No. Of Axes
3
Interface Type
I2C, SPI
Sensitivity Per Axis
1024LSB / G
Sensor Case Style
LGA
No. Of Pins
16
Supply Voltage Range
2.16V To 3.6V
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LIS3LV02DL
Manufacturer:
ST
Quantity:
20 000
LIS3LV02DL
7.24
7.25
FF_WU_DURATION (36h)
Table 58.
Table 59.
This register sets the minimum duration of the free-fall/wake-up event to be recognized.
DD_CFG (38h)
Table 60.
Table 61.
FWD7, FWD0
IEND
LIR
ZHIE
ZLIE
YHIE
YLIE
FWD7
IEND
Register (36h)
Register description (36h)
Register (38h)
Register description (38h)
FWD6
LIR
Interrupt enable on Direction change. Default value: 0
(0: disabled;
1: interrupt signal enabled)
Latch Interrupt request into DD_SRC reg with the DD_SRC reg cleared by reading
DD_ACK reg. Default value: 0.
(0: interrupt request not latched;
1: interrupt request latched)
Enable interrupt generation on Z High event. Default value: 0
(0: disable interrupt request;
1: enable interrupt request on measured accel. value higher than preset threshold)
Enable interrupt generation on Z Low event. Default value: 0
(0: disable interrupt request;
1: enable interrupt request on measured accel. value lower than preset threshold)
Enable interrupt generation on Y High event. Default value: 0
(0: disable interrupt request;
1: enable interrupt request on measured accel. value higher than preset threshold)
Enable interrupt generation on Y Low event. Default value: 0
(0: disable interrupt request;
1: enable interrupt request on measured accel. value lower than preset threshold)
Minimum duration of the Free-fall/Wake-up event
FWD5
ZHIE
Duration s ( )
FWD4
ZLIE
=
FF_WU_DURATION (Dec)
----------------------------------------------------------------------- -
FWD3
YHIE
ODR
FWD2
YLIE
Register description
FWD1
XHIE
FWD0
XLIE
39/48