TLA21000 Red Lion Controls, TLA21000 Datasheet - Page 3

no-image

TLA21000

Manufacturer Part Number
TLA21000
Description
Form-C Limit Relay W/1 Alarm
Manufacturer
Red Lion Controls
Type
Temperaturer
Datasheet

Specifications of TLA21000

Brand/series
TLA Series
Contact Form
SPST/SPDT
Dimensions
49.5mmW×49.5mmH×115.3mmD
Enclosure Rating
IP65
Input Type
RTD/Thermocouple
Ip Rating
IP65
Memory
EEPROM
Mounting Type
Panel
Number Of Outputs
1
Output Type
Relay
Power, Rating
8 VA
Primary Type
Controller
Special Features
EEPROM
Standards
cURus, CE, FM
Temperature, Ambient
0 to +50 °C (Max.)
Termination
Screw
Voltage, Rating
120⁄240 VAC
Voltage, Supply
85 to 250 VAC
Panel Cutout
1.77" × 1.77" (1⁄16 DIN)
Power Requirements
85-250 VAC
Sealing
NEMA 4X/IP65
Operating Temperature
0°C to +50°C
Lead Free Status / Rohs Status
RoHS Compliant part
OUTPUT SPECIFICATIONS
1. LIMIT AND ALARM OUTPUT RELAYS:
2. LIMIT OUTPUT: TLA21000: Form-C relay; TLA11100: Form-A relay.
ORDERING INFORMATION
Magnetic Interference (EMI), proper installation and wiring methods must be
followed to ensure compatibility in each application. The type of the electrical
noise, source or coupling method into the unit may be different for various
installations. Listed below are some EMC guidelines for successful installation
in an industrial environment.
1. The unit should be mounted in a metal enclosure, which is properly connected
2. Use shielded (screened) cables for all Signal and Control inputs. The shield
3. Never run Signal or Control cables in the same conduit or raceway with AC
4. Signal or Control cables within an enclosure should be routed as far away as
EMC INSTALLATION GUIDELINES
Contact Rating: 5 A @ 250 VAC or 30 VDC (resistive load) 1/10 HP @ 120
Life Expectancy: 100,000 cycles at max. load rating. (Decreasing load
Selectable for high or low trip activation. If the process temperature goes
above the limit setpoint for a high trip, or below the limit setpoint for a low
trip, the limit relay will de-energize to initiate a process shutdown. The limit
output cannot be reset until the process temperature returns to the proper
operating range; manual reset is required (local or remote).
Annunciators:
Although this unit is designed with a high degree of immunity to Electro
to protective earth.
(screen) pigtail connection should be made as short as possible. The
connection point for the shield depends somewhat upon the application.
Listed below are the recommended methods of connecting the shield, in order
of their effectiveness.
a. Connect the shield only at the panel where the unit is mounted to earth
b. Connect the shield to earth ground at both ends of the cable, usually when
c. Connect the shield to common of the unit and leave the other end of the
power lines, conductors feeding motors, solenoids, SCR controls, and
heaters, etc. The cables should be run in metal conduit that is properly
grounded. This is especially useful in applications where cable runs are long
and portable two-way radios are used in close proximity or if the installation
is near a commercial radio transmitter.
possible from contactors, control relays, transformers, and other noisy
components.
VAC (inductive load)
increases life expectancy.)
“EX” - Lit when the process temperature exceeds the limit setpoint.
“OUT” - Lit when the limit output is de-energized.
ground (protective earth).
the noise source frequency is above 1 MHz.
shield unconnected and insulated from earth ground.
85 to 250 VAC
18 to 36 VDC / 24 VAC
Form-C Relay
Form-A Relay
Form-C Relay
Form-A Relay
LIMIT OUTPUT
LIMIT OUTPUT
ALARM 1 OUTPUT
ALARM 1 OUTPUT
Form-A Relay
Form-A Relay
Form-A Relay
Form-A Relay
ALARM 2 OUTPUT
ALARM 2 OUTPUT
Form-A Relay
Form-A Relay
3
OUTPUT BOARD
OUTPUT BOARD
REPLACEMENT
REPLACEMENT
3. ALARM OUTPUTS (Optional): One or two Form-A relays.
RBDLA210
RBDLA210
5. In very electrically noisy environments, the use of external EMI suppression
6. Long cable runs are more susceptible to EMI pickup than short cable runs.
7. Switching of inductive loads produces high EMI. Use of snubbers across
RBD48111
RBD48111
Modes:
Reset Action: Programmable; automatic or latched. Latched alarms can be
Standby Mode: Programmable; enable or disable.
Hysteresis: Programmable.
Annunciator: “A1” and “A2” programmable for normal or reverse acting.
devices, such as ferrite suppression cores, is effective. Install them on Signal
and Control cables as close to the unit as possible. Loop the cable through the
core several times or use multiple cores on each cable for additional
protection. Install line filters on the power input cable to the unit to suppress
power line interference. Install them near the power entry point of the
enclosure.
The following EMI suppression devices (or equivalent) are recommended:
Ferrite Suppression Cores for signal and control cables:
Line Filters for input power cables:
Note: Reference manufacturer’s instructions when installing a line filter.
Therefore, keep cable runs as short as possible.
inductive loads suppresses EMI.
Snubbers:
Absolute High Acting
Deviation High Acting
Inside Band Acting
reset regardless of limit exceed condition.
Fair-Rite # 0443167251 (RLC #FCOR0000)
TDK # ZCAT3035-1330A
Steward #28B2029-0A0
Schaffner # FN610-1/07 (RLC #LFIL0000)
Schaffner # FN670-1.8/07
Corcom #1VR3
RLC #SNUB0000
PART NUMBERS
PART NUMBERS
TLA21000
TLA21010
TLA11100
TLA11110
Absolute Low Acting
Deviation Low Acting
Outside Band Acting