HT1MO2S3E3M-T NXP Semiconductors, HT1MO2S3E3M-T Datasheet - Page 20

no-image

HT1MO2S3E3M-T

Manufacturer Part Number
HT1MO2S3E3M-T
Description
RFID Modules & Development Tools HITAG 1 MOA2 MODULE
Manufacturer
NXP Semiconductors
Datasheet

Specifications of HT1MO2S3E3M-T

Operating Current
30 mA
Operating Voltage
3.1 V to 4.2 V
Product
RFID Transponders
Wireless Frequency
125 KHz
Dimensions
7.55 mm x 11.75 mm x 0.45 mm
Operating Temperature Range
- 25 C to + 85 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
HT1MOA2S30/E/3,118
7 Characterisation and Test of the Final Transponder
7.1 Characterisation of the Transponder
The parameters recommended to be characterised for the transponder are:
Parameter
Resonant frequency
Threshold value
Threshold value for READ
Threshold value for WRITE B
For the measurement of these parameters we recommend to use the test equipment available from
SCEMTEC, Marienheide-Rodt, Germany (Transponder Measurement System STM-1).
This device also supports functional testing (besides parameter testing). Therefore it can also be
used as production test equipment for the final transponder test. For further information please
contact Scemtec GmbH.
7.2 Final Test of the Transponder
In addition to the equipment described in the previous chapter Philips Semiconductors offers a
device for a final functional test of transponders, the HITAG
Parameter tests are not supportet by this device.
Basic flow for production and test:
1. Assembly of transponders
2. Functional test and final test of the EEPROM
Since the Keys and Logdata are changed during final test the Configuration and
personalization must take place after the final test. The final test is disabled (not reversible)
by setting the Tag-test mode bit to 0.
Ht1moa3.doc/HS
Specifications of the HT1 MOA3 S30
HITAG
For the final test of transponders we recommend to use the
Transponder Measurement System STM-1 of Scemtec.
TM
Test System HT OT490 of Philips Semiconductors or the
f
B
B
res
TH
RD
WR
Page 20 of 24
Comment
Transponder does not modulate
Resonant frequency @ T
Start of modulation
Command READ_PAGE OK
Command WRITE_PAGE OK
Rev. 1.1
TM
Test System HT OT490.
amb
= 22°C, @ B
TH
1997-08-19

Related parts for HT1MO2S3E3M-T