8845A/SU 120V Fluke Electronics, 8845A/SU 120V Datasheet - Page 19

PREC MLTMTR DMM BNCH 6.5 DIG RES

8845A/SU 120V

Manufacturer Part Number
8845A/SU 120V
Description
PREC MLTMTR DMM BNCH 6.5 DIG RES
Manufacturer
Fluke Electronics
Type
Digital (DMM)r
Datasheets

Specifications of 8845A/SU 120V

Includes
Test Leads
Style
Bench
Display Digits
6.5
Display Type
VFD, Dual
Display Count
Varies
Function
Voltage, Current, Resistance, Frequency
Functions, Extra
Continuity, dB, Diode Test
Features
Memory, RS-232
Ranging
Manual
Response
Average
Lead Free Status / RoHS Status
Contains lead / RoHS compliant by exemption
Other names
2675292
614-1001
General Specifications
Power
Voltage
Frequency ............................................................... 47 Hz to 440 Hz. Automatically sensed at power-on.
Power Consumption................................................ 28 VA peak (12 Watt average)
Dimensions
Height...................................................................... 88 mm (3.46 in.)
Width....................................................................... 217 mm (8.56 in.)
Depth ...................................................................... 297 mm (11.7 in.)
Weight..................................................................... 3.6 kg (8.0 lb)
Shipping Weight...................................................... 5.0 kg (11.0 lb)
Display
Vacuum Fluorescent Display, dot matrix
Environment
Temperature
Relative Humidity (non-condensing)
Altitude
Vibration and Shock................................................ Complies with Mil-T-28800F Type III, Class 5 (Sine only)
Safety
Designed to comply with IEC 61010-1:2000-1, UL 61010-1A1, CAN/CSA-C22.2 No. 61010.1, CAT I 1000V/CAT II 600V
EMC
Designed to comply with IEC 61326-1:2000-11 (EMC) when used with shielded communications cables. This Meter has
shown susceptibility to radiated frequencies greater than 1 V/m from 250 to 450 MHz.
Triggering
1259340
2441827
1540600
Model/Fluke PN
100 V Setting ...................................................... 90 V to 110 V
120 V Setting ...................................................... 108 V to 132 V
220 V Setting ...................................................... 198 V to 242 V
240 V Setting ...................................................... 216 V to 264 V
Operating ............................................................ 0 C to 55 C
Storage ............................................................... -40 C to 70 C
Warm Up............................................................. 1 hour to full uncertainty specifications
Operating ............................................................ 0 C to 28 C <90 %
Storage ............................................................... -40 C to 70 C <95 %
Operating ............................................................ 2,000 Meters
Storage ............................................................... 12,000 Meters
Samples per Trigger ........................................... 1 to 50,000
Agreement, Calibration, Accredited
Agreement, Calibration, primary standards lab
Agreement, Calibration, artifact
Table 1-5. Accessories (cont)
28 C to 40 C <80 %
40 C to 55 C <50 %
Description
Introduction and Specifications
General Specifications
1-9