DRT2-ID32BV-1 Omron, DRT2-ID32BV-1 Datasheet - Page 167

no-image

DRT2-ID32BV-1

Manufacturer Part Number
DRT2-ID32BV-1
Description
32 In Vert MIL Connector PNP
Manufacturer
Omron
Datasheet

Specifications of DRT2-ID32BV-1

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Connector Terminals with Transistors
146
1,2,3...
1,2,3...
2. Preparing the Sensor or External Device Cables
Using Tyco Electronics Amp or Sumitomo 3M Connectors
The sensor and external device cables for connector output with transistors
are normally either semi-stripped or stripped, as shown in the following dia-
gram.
When the cables are prepared this way, a Cable Connector cannot be
attached, so first cut the end and remove the cable sheath as shown in the fol-
lowing diagram. (Do not strip the core wires.)
Using OMRON Connectors
Align the cable with the strip gauge on the side of the connector. Remove 7 to
8 mm of the wiring sheath, and twist the exposed wires several times.
3. Inserting the Wire into the Cable Connector (Hard Wiring Procedure)
Using Tyco Electronics Amp or Sumitomo 3M Connectors
1. Insert the wire into the cover of the Cable Connector. Check that the termi-
2. Join the cover and plug connector, using pliers or another tool to push in
Using OMRON Connectors
1. Use a flat-blade screwdriver to push the operation lever inside the connec-
Semi-stripped cable
nal number and wire color match, and insert all the way to the back of the
connector.
fully. At the same time, push in the middle of the cover straight so that it is
not crooked.
tor's operation opening until it locks, as shown in the following diagram.
7 to 8 mm
20 mm min.
Operating opening
Stripped cable
Flat-blade screwdriver
Section 5-6

Related parts for DRT2-ID32BV-1