1141A AGILENT TECHNOLOGIES, 1141A Datasheet - Page 23

Differential Oscilloscope Probe

1141A

Manufacturer Part Number
1141A
Description
Differential Oscilloscope Probe
Manufacturer
AGILENT TECHNOLOGIES
Datasheet

Specifications of 1141A

Bandwidth
200MHz
For Use With
Agilent Technologies 6000 & DSO5000 Series Oscilloscopes
Lead Free Status / RoHS Status
na
N2744A T2A Probe Interface Adapter
• Enables Tektronix TekProbe-BNC
• An easy-to-use plug-on adapter
• Provides necessary probe power,
The N2744A T2A interface adapter
enables selected TekProbe
level 2 probes to be used with
Agilent oscilloscopes with AutoProbe
interface. Existing TekProbe-BNC
probe types can simply be plugged
into the T2A adapter which is then
plugged directly into any AutoProbe
input channel on an InfiniiVision or
Infiniium oscilloscope. Select the
probe model in the scope menu and
the Agilent oscilloscope sets up the
attenuation factor and the probe
type automatically. The T2A interface
adapter supplies the necessary
probe power, calibration (for selected
models only) and offset control as
used by the connected TekProbe
probe. The adapter is targeted for
customers using both Tek active
probes with TekProbe-BNC level 2
interfaces and Agilent oscilloscopes
with the AutoProbe interface.
Tek probe compatibility
The N2744A T2A adapter supports
only the probes listed below with
TekProbe interfaces.
AC/DC current probe
TCP202 50-MHz AC/DC current probe
level 2 probes to connect to
Agilent’s AutoProbe interface on
InfiniiVision 5000, 6000, 7000, and
Infiniium 9000, 90000 oscilloscopes
to the Agilent oscilloscope’s
AutoProbe interface
calibration, and offset control as
needed to the attached TekProbe
probe
®
interface
Single-ended active probes
P6243
P6245
P6205
P6241
P6249
Differential active probes
P6246
P6247
P6248
P6250
P6251
Single-ended active probe,
1 GHz, 10:1 without offset
control
Single-ended active probe,
1.5 GHz, 10:1 with offset
control
Single-ended active probe,
750 MHz, 10:1 without offset
control
Single-ended active probe,
4 GHz, 10:1 with offset
control
Single-ended active probe,
4 GHz, 5:1 with offset control
400 MHz, 10:1/1:1 with offset
control
1 GHz, 10:1/1:1 with offset
control
1.5 GHz, 10:1/1:1 with offset
control
500 MHz, 50:1/5:1 with offset
control
1 GHz, 50:1/5:1 with offset
control
23
Agilent scope
• Agilent InfiniiVision 3000 X-Series
• Agilent InfiniiVision 5000, 6000, and
• Agilent Infiniium 8000, 9000, 80000,
Ordering information
N2744A T2A probe interface adapter
7000 Series and future revisions
(except 6000 100-MHz) with software
version 06.15 or higher
90000 Series with software version
03.10 or higher
compatibility