MC9S12XDT512CAA Freescale, MC9S12XDT512CAA Datasheet - Page 415

no-image

MC9S12XDT512CAA

Manufacturer Part Number
MC9S12XDT512CAA
Description
Manufacturer
Freescale
Datasheet

Specifications of MC9S12XDT512CAA

Cpu Family
HCS12
Device Core Size
16b
Frequency (max)
40MHz
Interface Type
CAN/I2C/SCI/SPI
Total Internal Ram Size
32KB
# I/os (max)
59
Number Of Timers - General Purpose
12
Operating Supply Voltage (typ)
2.5/5V
Operating Supply Voltage (max)
2.75/5.5V
Operating Supply Voltage (min)
2.35/3.15V
On-chip Adc
8-chx10-bit
Instruction Set Architecture
CISC
Operating Temp Range
-40C to 85C
Operating Temperature Classification
Industrial
Mounting
Surface Mount
Pin Count
80
Package Type
PQFP
Program Memory Type
Flash
Program Memory Size
512KB
Lead Free Status / RoHS Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MC9S12XDT512CAA
Manufacturer:
FREESCALE
Quantity:
2 235
Part Number:
MC9S12XDT512CAA
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
MC9S12XDT512CAA
Manufacturer:
FREESCALE
Quantity:
2 235
Part Number:
MC9S12XDT512CAAR
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
9.7.1.4
A data transfer ends with a STOP signal generated by the 'master' device. A master transmitter can simply
generate a STOP signal after all the data has been transmitted. The following is an example showing how
a stop condition is generated by a master transmitter.
If a master receiver wants to terminate a data transfer, it must inform the slave transmitter by not
acknowledging the last byte of data which can be done by setting the transmit acknowledge bit (TXAK)
before reading the 2nd last byte of data. Before reading the last byte of data, a STOP signal must be
generated first. The following is an example showing how a STOP signal is generated by a master receiver.
9.7.1.5
At the end of data transfer, if the master continues to want to communicate on the bus, it can generate
another START signal followed by another slave address without first generating a STOP signal. A
program example is as shown.
9.7.1.6
In the slave interrupt service routine, the module addressed as slave bit (IAAS) should be tested to check
if a calling of its own address has just been received. If IAAS is set, software should set the transmit/receive
mode select bit (Tx/Rx bit of IBCR) according to the R/W command bit (SRW). Writing to the IBCR
clears the IAAS automatically. Note that the only time IAAS is read as set is from the interrupt at the end
of the address cycle where an address match occurred, interrupts resulting from subsequent data transfers
will have IAAS cleared. A data transfer may now be initiated by writing information to IBDR, for slave
transmits, or dummy reading from IBDR, in slave receive mode. The slave will drive SCL low in-between
byte transfers, SCL is released when the IBDR is accessed in the required mode.
Freescale Semiconductor
MASTX
END
EMASTX
MASR
LAMAR
ENMASR
NXMAR
RESTART
DEC
BEQ
MOVB
DEC
BNE
BSET
BRA
BCLR
MOVB
RTI
Generation of STOP
Generation of Repeated START
BSET
MOVB
Slave Mode
TST
BEQ
BRSET
MOVB
DEC
BRA
BCLR
RTI
TXCNT
END
IBSR,#$01,END
DATABUF,IBDR
TXCNT
EMASTX
IBCR,#$20
RXCNT
ENMASR
RXCNT,D1
D1
NXMAR
IBCR,#$08
NXMAR
IBCR,#$20
IBDR,RXBUF
IBCR,#$04
CALLING,IBDR
MC9S12XDP512 Data Sheet, Rev. 2.21
;DECREASE THE RXCNT
;LAST BYTE TO BE READ
;CHECK SECOND LAST BYTE
;TO BE READ
;NOT LAST OR SECOND LAST
;SECOND LAST, DISABLE ACK
;TRANSMITTING
;LAST ONE, GENERATE ‘STOP’ SIGNAL
;READ DATA AND STORE
;ANOTHER START (RESTART)
;TRANSMIT THE CALLING ADDRESS;D0=R/W
;GET VALUE FROM THE TRANSMITING COUNTER
;END IF NO MORE DATA
;END IF NO ACK
;TRANSMIT NEXT BYTE OF DATA
;DECREASE THE TXCNT
;EXIT
;GENERATE A STOP CONDITION
;RETURN FROM INTERRUPT
Chapter 9 Inter-Integrated Circuit (IICV2) Block Description
415

Related parts for MC9S12XDT512CAA