PIC18F86K90-I/PT Microchip Technology, PIC18F86K90-I/PT Datasheet - Page 297

no-image

PIC18F86K90-I/PT

Manufacturer Part Number
PIC18F86K90-I/PT
Description
64kB Flash, 4kB RAM, 1kB EE, 16MIPS, NanoWatt XLP, LCD, 5V 80 TQFP 12x12x1mm TRA
Manufacturer
Microchip Technology
Series
PIC® XLP™ 18Fr

Specifications of PIC18F86K90-I/PT

Core Processor
PIC
Core Size
8-Bit
Speed
64MHz
Connectivity
I²C, LIN, SPI, UART/USART
Peripherals
Brown-out Detect/Reset, LCD, POR, PWM, WDT
Number Of I /o
69
Program Memory Size
64KB (32K x 16)
Program Memory Type
FLASH
Eeprom Size
1K x 8
Ram Size
4K x 8
Voltage - Supply (vcc/vdd)
1.8 V ~ 5.5 V
Data Converters
A/D 24x12b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
80-TQFP
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PIC18F86K90-I/PT
Manufacturer:
Microchip Technology
Quantity:
10 000
Part Number:
PIC18F86K90-I/PT
Manufacturer:
MICROCHIP/微芯
Quantity:
20 000
Company:
Part Number:
PIC18F86K90-I/PT
Quantity:
492
Part Number:
PIC18F86K90-I/PTRSL
Manufacturer:
Microchip Technology
Quantity:
10 000
20.10 Operation During Sleep
The LCD module can operate during Sleep. Setting the
SLPEN bit (LCDCON<6>) allows the LCD module to go
to Sleep. Clearing this bit allows the module to continue
operating during Sleep.
If a SLEEP instruction is executed and SLPEN = 1, the
LCD module will cease all functions and go into a very
low-current consumption mode. The module will stop
operation immediately and drive the minimum LCD volt-
age on both segment and common lines. Figure 20-19
shows this operation.
The LCD module current consumption will not
decrease in this mode, but the overall consumption of
the device will be lower due to shut down of the core
and other peripheral functions.
To ensure that no DC component is introduced on the
panel, the SLEEP instruction should be executed
immediately after an LCD frame boundary. The LCD
FIGURE 20-19:
 2010 Microchip Technology Inc.
COM0
COM1
COM2
SEG0
SLEEP ENTRY/EXIT WHEN SLPEN = 1 OR CS<1:0> = 00
2 Frames
SLEEP Instruction Execution
Preliminary
PIC18F87K90 FAMILY
interrupt can be used to determine the frame boundary.
For the formulas to calculate the delay, see
Section 20.9 “LCD Interrupts”.
If a SLEEP instruction is executed and SLPEN = 0, the
module will continue to display the current contents of
the LCDDATA registers. The LCD data cannot be
changed.
To allow the module to continue operation while in
Sleep, the clock source must be either the internal RC
oscillator or Timer1 external oscillator.
If the system clock is selected and the module is
programmed to not Sleep, the module will ignore the
SLPEN bit and stop operation immediately. The
minimum LCD voltage then will be driven onto the
segments and commons.
Note:
Wake-up
The internal RC oscillator or external
SOSC oscillator must be used to operate
the LCD module during Sleep.
DS39957B-page 297