MT46H16M32LFCM-75 Micron Technology Inc, MT46H16M32LFCM-75 Datasheet - Page 52

MT46H16M32LFCM-75

Manufacturer Part Number
MT46H16M32LFCM-75
Description
Manufacturer
Micron Technology Inc
Type
DDR SDRAMr
Datasheet

Specifications of MT46H16M32LFCM-75

Organization
16Mx32
Density
512Mb
Address Bus
15b
Access Time (max)
6.5/6ns
Maximum Clock Rate
133MHz
Operating Supply Voltage (typ)
1.8V
Package Type
VFBGA
Operating Temp Range
0C to 70C
Operating Supply Voltage (max)
1.95V
Operating Supply Voltage (min)
1.7V
Supply Current
100mA
Pin Count
90
Mounting
Surface Mount
Operating Temperature Classification
Commercial
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MT46H16M32LFCM-75
Manufacturer:
MICRON
Quantity:
20 000
Part Number:
MT46H16M32LFCM-75 AT
Manufacturer:
MICRON
Quantity:
4 000
Part Number:
MT46H16M32LFCM-75 IT
Manufacturer:
Micron Technology Inc
Quantity:
10 000
Part Number:
MT46H16M32LFCM-75 IT
Manufacturer:
MICRON
Quantity:
20 000
Part Number:
MT46H16M32LFCM-75AT
Manufacturer:
MICRON
Quantity:
1 850
Part Number:
MT46H16M32LFCM-75IT
Manufacturer:
MICRON
Quantity:
1 852
Part Number:
MT46H16M32LFCM-75L
Manufacturer:
MICRON
Quantity:
1 852
Part Number:
MT46H16M32LFCM-75LIT
Manufacturer:
MICRON
Quantity:
1 852
Burst Type
Table 21: Burst Definition Table
PDF: 09005aef82d5d305
512mb_ddr_mobile_sdram_t47m.pdf – Rev. I 12/09 EN
Length
Burst
16
2
4
8
A3
Starting Column Address
A2
A2
0
0
0
0
1
1
1
1
tions that can be accessed for a given READ or WRITE command. Burst lengths of 2, 4,
8, or 16 locations are available for both sequential and interleaved burst types.
When a READ or WRITE command is issued, a block of columns equal to the burst
length is effectively selected. All accesses for that burst take place within this block,
meaning that the burst will wrap when a boundary is reached. The block is uniquely
selected by A[i:1] when BL = 2, by A[i:2] when BL = 4, by A[i:3] when BL = 8, and by A[i:4]
when BL = 16, where Ai is the most significant column address bit for a given configura-
tion. The remaining (least significant) address bits are used to specify the starting
location within the block. The programmed burst length applies to both READ and
WRITE bursts.
Accesses within a given burst can be programmed to be either sequential or interleaved
via the standard mode register.
The ordering of accesses within a burst is determined by the burst length, the burst
type, and the starting column address.
A1
A1
A1
0
0
1
1
0
0
1
1
0
0
1
1
A0
A0
A0
A0
0
1
0
1
0
1
0
1
0
1
0
1
0
1
Type = Sequential
52
0-1-2-3-4-5-6-7
1-2-3-4-5-6-7-0
2-3-4-5-6-7-0-1
3-4-5-6-7-0-1-2
4-5-6-7-0-1-2-3
5-6-7-0-1-2-3-4
6-7-0-1-2-3-4-5
7-0-1-2-3-4-5-6
0-1-2-3
1-2-3-0
2-3-0-1
3-0-1-2
512Mb: x16, x32 Mobile LPDDR SDRAM
0-1
1-0
Order of Accesses Within a Burst
Micron Technology, Inc. reserves the right to change products or specifications without notice.
Standard Mode Register
Type = Interleaved
© 2004 Micron Technology, Inc. All rights reserved.
0-1-2-3-4-5-6-7
1-0-3-2-5-4-7-6
2-3-0-1-6-7-4-5
3-2-1-0-7-6-5-4
4-5-6-7-0-1-2-3
5-4-7-6-1-0-3-2
6-7-4-5-2-3-0-1
7-6-5-4-3-2-1-0
0-1-2-3
1-0-3-2
2-3-0-1
3-2-1-0
0-1
1-0