STM32W108HBU6 STMicroelectronics, STM32W108HBU6 Datasheet - Page 123

no-image

STM32W108HBU6

Manufacturer Part Number
STM32W108HBU6
Description
Manufacturer
STMicroelectronics
Datasheet

Specifications of STM32W108HBU6

Operating Temperature (min)
-40C
Operating Temperature (max)
85C
Processing Unit
Microprocessor
Operating Supply Voltage (min)
1.18V
Operating Supply Voltage (typ)
1.25V
Operating Supply Voltage (max)
1.32V
Package Type
VFQFPN EP
Pin Count
40
Mounting
Surface Mount
Rad Hardened
No
Lead Free Status / Rohs Status
Supplier Unconfirmed

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
STM32W108HBU6
Manufacturer:
ST
0
Part Number:
STM32W108HBU61TR
Manufacturer:
ST
0
Part Number:
STM32W108HBU63
Manufacturer:
ST
Quantity:
201
Part Number:
STM32W108HBU63TR
Manufacturer:
ST
0
Part Number:
STM32W108HBU64
Manufacturer:
ST
0
Part Number:
STM32W108HBU64TR
Manufacturer:
TDK
Quantity:
30 000
Part Number:
STM32W108HBU64TR
Manufacturer:
ST
0
STM32W108CB, STM32W108HB
General-purpose timers
The timer is able to generate PWM in edge-aligned mode or center-aligned mode
depending on the TIM_CMS bits in the TIMx_CR1 register.
PWM edge-aligned mode: up-counting configuration
Up-counting is active when the TIM_DIR bit in the TIMx_CR1 register is low. Refer to
Up-
counting mode on page
108.
The following example uses PWM mode 1. The reference PWM signal OCyREF is high as
long as TIMx_CNT < TIMx_CCRy, otherwise it becomes low. If the compare value in
TIMx_CCRy is greater than the auto-reload value in TIMx_ARR, then OCyREF is held at 1.
If the compare value is 0, then OCyREF is held at 0.
Figure 35
shows some edge-aligned
PWM waveforms in an example, where TIMx_ARR = 8.
Figure 35. Edge-aligned PWM waveforms (ARR = 8)
PWM edge-aligned mode: down-counting configuration
Down-counting is active when the TIM_DIR bit in the TIMx_CR1 register is high. Refer to
Down-counting mode on page 110
for more information.
In PWM mode 1, the reference signal OCyREF is low as long as TIMx_CNT > TIMx_CCRy,
otherwise it becomes high. If the compare value in TIMx_CCRy is greater than the auto-
reload value in TIMx_ARR, then OCyREF is held at 1. Zero-percent PWM is not possible in
this mode.
PWM center-aligned mode
Center-aligned mode is active except when the TIM_CMS bits in the TIMx_CR1 register are
00 (all configurations where TIM_CMS is non-zero have the same effect on the
OCyREF/OCy signals). The compare flag is set when the counter counts up, when it counts
down, or when it counts up and down, depending on the TIM_CMS bits configuration. The
direction bit (TIM_DIR) in the TIMx_CR1 register is updated by hardware and must not be
changed by software. Refer to
Center-aligned mode (up/down counting) on page 111
for
more information.
Doc ID 16252 Rev 7
123/208

Related parts for STM32W108HBU6