FHDFEET Intel, FHDFEET Datasheet - Page 25

no-image

FHDFEET

Manufacturer Part Number
FHDFEET
Description
Manufacturer
Intel
Datasheet

Specifications of FHDFEET

Lead Free Status / Rohs Status
Supplier Unconfirmed
There is a single bi-color LED to indicate power supply status of each module. When AC is applied
to the power supply module and standby voltages are available, the LED will blink GREEN. The
LED turns on GREEN to indicate that all the power outputs are available. The LED turns on
AMBER to indicate that the power supply has failed, shutdown due to over current, shutdown due
to over temperature, or is indicating a predictive failure. Listed below are the LED indicators for
conditions of the 350-W TPS module LEDs.
Note: The SC5200 HSRP Chassis ships in a non-redundant, 2+0 configuration with modules #2
and #3 installed. The single power cord should be inserted in AC2 inlet to ensure that the power
supply is providing 650 watts of power. If the power cord is connected to AC1, module #2 should
be moved to the #1 position (see Figure 12). Other combinations are invalid and will degrade the
power supply to 350 watts as shown in Table 5. Adding a second power cord will allow for any
combination of two modules, but does not provide redundant operation unless the third power
supply module is also added.
Revision 1.0
No AC1 or AC2 power input
No AC power to this PS module only
AC present / Only Standby Outputs On
Power supply DC outputs ON and OK
Power supply failure (includes over voltage, over temperature)
Current limit
AC1
ON
ON
ON
Figure 14. Replaceable 350-W Thin Power Supply Module
Table 5. Non-Redundant Power Supply Configurations
AC2
ON
ON
ON
Power Supply Condition
Table 4. 350-W TPS Module LED Indicator
Module 1
GREEN
GREEN
AMBER
AMBER
Module 2
AMBER
AMBER
GREEN
GREEN
Module 3
GREEN
GREEN
GREEN
GREEN
OFF
AMBER
BLINK GREEN
GREEN
AMBER
AMBER
Power Supply LED
Output wattage
650 W
350 W
350 W
650 W
350 W
350 W