Intel Desktop Board D865PERL Technical Product Specification
2.12 Thermal Considerations
80
CAUTION
The use of an Intel Pentium 4 processor operating above 2.80 GHz with this Intel desktop board
requires the following:
Failure to ensure appropriate airflow may result in reduced performance of both the processor
and/or voltage regulator or, in some instances, damage to the desktop board. For a list of chassis
that have been tested with Intel desktop boards please refer to the following website:
http://developer.intel.com/design/motherbd/cooling.htm
All responsibility for determining the adequacy of any thermal or system design remains solely
with the reader. Intel makes no warranties or representations that merely following the
instructions presented in this document will result in a system with adequate thermal performance.
CAUTION
Ensure that the ambient temperature does not exceed the Desktop Board D865PERL’s maximum
operating temperature. Failure to do so could cause components to exceed their maximum case
temperature and malfunction. For information about the maximum operating temperature, see the
environmental specifications in Section 2.14.
CAUTION
Ensure that proper airflow is maintained in the processor voltage regulator circuit. Failure to do
so may result in damage to the voltage regulator circuit. The processor voltage regulator area
(item A in Figure 30) can reach a temperature of up to 85 °C in an open chassis.
A chassis with appropriate airflow to ensure proper cooling of the components on the board
A processor fan heatsink that meets the thermal performance targets for Pentium 4 processors
operating above 2.80 GHz