DESCRIPTION:
If a write to any I/O data register (data, clear, set and toggle registers) occurs one system clock cycle after an edge is detected on an edge-
triggered interrupt, then the bit may be cleared one system clock cycle after it has been set.
If the bit has been programmed to generate an interrupt, then the interrupt will occur, but there will be no indication of which bit
signalled the interrupt. The interrupt will be lost if the core clock is not running or if the SIC_IMASK bit is not set to enable the interrupt.
WORKAROUND:
If only one edge-sensitive source is assigned to one interrupt, it can be assumed to be the source of the interrupt and a read instruction of
SIC_ISR and the I/O registers is not required. Note that all interrupts are properly executed, when enabled.
Use level-sensitive interrupts instead of edge-sensitive interrupts. Toggle the polarity between received edges to prevent re-entry of the
interrupt service routine and to sensitize for the next edge. This is applicable when the latency between two edges is sufficient to serve
the interrupt service routine or can be used for request lines. Toggling polarity can be used when looking for both edges. For only one
edge, however, the other interrupt must be ignored.
APPLIES TO REVISION(S):
0.3, 0.4, 0.5
DESCRIPTION:
If a peripheral (PPI, SPORT, SPI, etc.) is disabled while DMA is running and before the associated DMA channel is disabled, the DMA system
may be corrupted. In applications with multiple DMA channels running concurrently, this anomaly manifests itself with missing data or
shuffled data being transferred. Although the anomaly also affects applications with a single DMA channel, its effects may not be visible if
the peripheral is being shut down by the user code.
WORKAROUND:
If the DMA channel is running, disable the peripheral's associated DMA channel before disabling the peripheral itself.
If the DMA channel is stopped, the peripheral must be disabled before the associated DMA channel is disabled. When a channel is
disabled, the DMA unit ignores the peripheral interrupt and passes it directly to the interrupt controller, thus generating spurios
interrupts.
APPLIES TO REVISION(S):
0.3, 0.4, 0.5
05000277 - Writes to an I/O Data Register One SCLK Cycle after an Edge Is Detected May Clear Interrupt:
05000278 - Disabling Peripherals with DMA Running May Cause DMA System Instability: