NE1619DS NXP Semiconductors, NE1619DS Datasheet - Page 11

no-image

NE1619DS

Manufacturer Part Number
NE1619DS
Description
Board Mount Temperature Sensors I2C LOC +/-3 AND REM +/-5 TS W/VM
Manufacturer
NXP Semiconductors
Datasheet

Specifications of NE1619DS

Full Temp Accuracy
+/- 2 C , +/- 3 C
Package / Case
SSOP-16
Digital Output - Bus Interface
2-Wire
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
0 C
Output Type
Digital
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
NE1619DS,112

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
NE1619DS
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Company:
Part Number:
NE1619DS
Quantity:
5 000
Part Number:
NE1619DSЈ¬112
Manufacturer:
NXP
Quantity:
1 290
Philips Semiconductors
Table 2. Configuration Register (CR, 40h, default = 0000 1000)
Table 3. Status Register 1 (SR1, 41h, default = 0000 0000)
Table 4. Status Register 2 (SR2, 42h, default = 0000 0000)
Table 5. VID (VID, 47h, default = 0000 VID[3:0] )
Table 6. VID4 (VID4, 49h, default = 1000 000VID[4] )
2004 Oct 05
HECETA4 Temperature and voltage monitor
BIT
BIT
BIT
BIT
0–3
4–6
BIT
1–7
0
1
2
3
4
5
6
7
0
1
2
3
4
5
6
7
0
1
2
3
4
5
6
7
7
0
START
Reserved
Reserved
Reserved
RESET
12V
SELECT
Reserved
Initialization
+2.5V_ERROR
VCCP_ERROR
+3.3V_ERROR
+5V_ERROR
Internal Temp Error
External Temp Error
Reserved
Reserved
+12V_ERROR
VDD_ERROR
Reserved
Reserved
Reserved
Reserved
Remote Diode Fault
Reserved
VID[0:3]
Reserved
RESET ENABLE
VID4
Reserved
IN
/VID4
NAME
NAME
NAME
NAME
NAME
Read
Read
Read
Read
Read
Read
Read
Read
Read
Read
Read
Read
Read
Read
Read
Read
Read
Read
Read
Read
Read
Read
Read
Read
Read
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Logic 1 enables startup of monitor device, logic 0 places the device in standby mode.
Power–up default = 0.
At startup, limit checking functions and scanning begins. Note, all High and Low limits
should be set into the ASIC prior turning on this bit.
Power-up default = 0.
Power-up default = 0.
Power-up default = 1.
Setting this bit generates a minimum 20ms low pulse on the Reset pin, if the reset
function is enabled. Power-up default = 0.
Selects whether pin 11 acts as a 12 volt analog input monitoring pin, or as a VID[4] input.
This pin defaults to the 12 volt analog input. Power–up default = 0.
Power–up default = 0.
Logic 1 restores power–up default values to the configuration register and the status
registers. This bit automatically clears itself. Power–up default = 0.
A one indicates 2.5V
A one indicates V
A one indicates 3.3V
A one indicates 5V
A one indicates internal or local temp High or Low limit has been exceeded.
A one indicates external or remote temp High or Low limit has been exceeded.
A one indicates 12V
A one indicates V
Undefined.
Undefined.
Undefined.
Undefined.
A one indicates either a short or open circuited fault on the remote thermal diode inputs.
Undefined.
The VID[0:3] inputs from Pentium/PRO power supplies ID to indicate the operating
voltage (e.g. 1.5V to 2.9V). Power-up default = VID[0:3].
Undefined.
When set to 1, enables the RESET pin output function.
This bit defaults to 0 at Power–up and enables addressing function.
VID4 input, if selected, from Pentium/PRO power supplied ID.
Power-up default = 0 and pin 11 is not selected for VID4.
Power-up default = 1000 000
CCPVIN
DD
11
IN
IN
IN
IN
High or Low limit has been exceeded.
High or Low limit has been exceeded.
High or Low limit has been exceeded.
High or Low limit has been exceeded.
High or Low limit has been exceeded.
High or Low limit has been exceeded.
DESCRIPTION
DESCRIPTION
DESCRIPTION
DESCRIPTION
DESCRIPTION
Product data sheet
NE1619

Related parts for NE1619DS