VQ1301N-51 SMC Corporation, VQ1301N-51 Datasheet - Page 46

no-image

VQ1301N-51

Manufacturer Part Number
VQ1301N-51
Description
SOLENOID VALVE, BASE MT, 5 PORT, PLUG-IN TYPE, 24VDC, 3 POSITION CLOSED CENTER
Manufacturer
SMC Corporation
Type
Solenoidr
Datasheet

Specifications of VQ1301N-51

Brand/series
VQ Series
Configuration
3-Position Closed Center
Enclosure Rating
IP65
Fluid Type
Air/Inert Gas
Number Of Ports
5
Pressure, Operating
0.7 MPa
Primary Type
Solenoid Valve
Temperature, Ambient
–10° to +50°C
Valve Type
5-Port Solenoid, Plug-In, Base Mounted with 3 Position Closed Center Actuation, Rubber Seal, Negative Common
Voltage, Coil
24 VDC
SI Unit Part No.
(Without option W [Dust-protected (-XP) is included.])
45
b
b
How to Order Manifold
Note 1) Refer to page 56 for details.
Note 2) Max. 16 stations. (Specify a
Symbol
16
MM
CM
Refer to Best Pneumatics No. q for details on the EX120/123/124 integrated-type (Output) serial transmission system.
S
Cylinder port
Symbol
R1
R2
F1
J1
J2
Q
Enclosure: Dust-tight, Water-jet-proof (IP65) compatible
VV5Q
H
V
The serial transmission system reduces wiring work,
while minimizing wiring and saving space.
(Series VQ2000)
02
IP65 compliant
C3
C4
C6
C8
M5
Note)
1
Note 3)
Note 4)
model with 9 to 16 stations
by means of the manifold
specification sheet.)
1
2
Note 1) Insert “L” (Top ported) or “B” (Bottom ported) for elbow type.
Note 2) Indicate as “LM” for models with elbow fittings and mixed cylinder port sizes.
Note 3) Indicate “Mixed sizes and with port plug” by means of the manifold specification sheet.
Note 4) When selecting the mixed size for different types of piping, dual flow fitting assembly, or
Note 5) Inch-size one-touch fittings are available. Refer to “Semi-standard” on page 57 for details.
NKE Corp.: Uni-wire System
NKE Corp.: Uni-wire H System
SUNX Corp.: S-LINK
SUNX Corp.: S-LINK
(8 outputs)
DeviceNet™
OMRON Corp.: CompoBus/S
(16 outputs)
OMRON Corp.: CompoBus/S
(8 outputs)
CC-LINK
(16 outputs)
Series
16 stations
Stations
Plug-in unit
VQ1000
VQ2000
2 stations
Mixed sizes and with port plug
Mixed size for different types of piping, option installed
Manifold
Series
With ø3.2 one-touch fitting
kit (Serial transmission): For EX120/123/124 Integrated-type (Output) serial transmission system
With ø4 one-touch fitting
With ø6 one-touch fitting
With ø8 one-touch fitting
Example) B6 (Bottom ported elbow with ø6 one-touch fitting)
double check block (direct mounting), enter “MM” and give instructions in the manifold
specification sheet.
1
Protocol
M5 thread
Port size
1
VQ1000/2000
08 C6
Standard:
Dust-protected:
Standard:
Dust-protected:
Standard:
Dust-protected:
Standard:
Dust-protected:
Standard:
Dust-protected: No part no.
Standard:
Dust-protected:
Standard:
Dust-protected:
Standard:
Dust-protected:
Symbol
SI unit specifications
R1
R2
VQ1000 VQ2000
F1
J1
J2
H
Q
V
0
SI unit part no.
EX120-SUW1
EX120-SUH1
EX120-SSL1
EX120-SSL2
EX120-SDN1
EX120-SCS1
EX120-SCS2
EX120-SMJ1
Without SI unit
NKE Corp.: Uni-wire System
NKE Corp.: Uni-wire H System
SUNX Corp.: S-LINK (16 outputs)
SUNX Corp.: S-LINK (8 outputs)
DeviceNet™ System
OMRON Corp.: CompoBus/S (16 outputs)
OMRON Corp.: CompoBus/S (8 outputs)
CC-LINK
S
EX120-SUW1-XP
EX120-SUH1-XP
EX120-SSL1-XP
EX120-SSL2-XP
EX120-SCS1-XP
EX120-SCS2-XP
EX120-SMJ1-XP
V
Protocol
CE compliant
XP
Dust-protected (-XP)
Suffix “-XP” to the end of the part number for the
dust-protected SI units.
(Except Q when the SI unit specifications are
compatible with DeviceNet™.)
SI Unit Part No. (With option W)
Symbol
R1
R2
F1
J1
J2
H
Q
V
Manifold Specifications
VQ1000
VQ2000
NKE Corp.: Uni-wire System
NKE Corp.: Uni-wire H System
SUNX Corp.: S-LINK (16 outputs)
SUNX Corp.: S-LINK (8 outputs)
DeviceNet™ System
OMRON Corp.: CompoBus/S (16 outputs)
OMRON Corp.: CompoBus/S (8 outputs)
CC-LINK
Series
Max. 16 stations
Max. 8 stations
Max. 8 stations
Stations
Max.16
Max.16
stations
stations
direction
Piping
Protocol
Side
Side
D„
G1
G2
G3
J„
W
B
R
Symbol
K
Option
Nil
Note 2)
Note 7)
Piping specifications
Note 8)
Note 9)
D
Note 6)
N
S
Note 4)
Note 4)
Note 4)
Note 5)
Note 1) When two or more symbols are specified,
Note 2) Models with a suffix “-B” have check valves for
Note 3)
Note 4) Specify the mounting position by means of
Note 5) Refer to page 69 for details on with vacuum
Note 6) Specify the wiring specifications by means of
Note 7) Indicate “R” for the valve with external pilot.
Note 8) A combination of “W” and “XP” is unavailable.
Note 9) Refer to “Dimensions” on page 48 for SI unit
Note 3)
1(P), 3(R)
C10
C8
Special wiring specifications
With back pressure check valve
Direct EXH outlet with built-in silencer
2 sets of regulator unit
3 sets of regulator unit
(Except double wiring)
indicate them alphabetically.
Example) -BRS.
prevention of back pressure at all manifold sta-
tions. When a back pressure check valve is de-
sired, and is to be installed only in certain
manifold stations, specify the mounting position
by means of the manifold specification sheet.
The number of stations that may be displayed
is longer than the manifold number of stations.
the manifold specification sheet.
ejector unit. A combination of “J” and “N” is
not available.
the manifold specification sheet.
and valve, in case of W (Dust-tight, Water-jet-
proof).
(„: Stations 02 to 24)
Enclosure: Dust-tight,
Water-jet-proof (IP65)
1 set of regulator unit
With external pilot
DIN rail mounting
DIN rail mounting
With ejector unit
With name plate
Port size
C3, C4, C6, M5
Option
None
C4, C6, C8
4(A), 2(B)
EX123D-SUW1
EX123D-SUH1
EX123D-SSL1
EX123D-SSL2
EX124D-SDN1
EX124D-SCS1
EX124D-SCS2
EX124D-SMJ1
SI unit part no. CE compliant
CE compliant
Refer to “SI Unit Part
No.” when ordering the
CE-compliant SI unit.
Nil
Q
CE compliant
VQ1000 VQ2000
Max. 16 stations
Max. 16 stations
Applicable
stations

Related parts for VQ1301N-51