VQ1301N-51 SMC Corporation, VQ1301N-51 Datasheet - Page 70

no-image

VQ1301N-51

Manufacturer Part Number
VQ1301N-51
Description
SOLENOID VALVE, BASE MT, 5 PORT, PLUG-IN TYPE, 24VDC, 3 POSITION CLOSED CENTER
Manufacturer
SMC Corporation
Type
Solenoidr
Datasheet

Specifications of VQ1301N-51

Brand/series
VQ Series
Configuration
3-Position Closed Center
Enclosure Rating
IP65
Fluid Type
Air/Inert Gas
Number Of Ports
5
Pressure, Operating
0.7 MPa
Primary Type
Solenoid Valve
Temperature, Ambient
–10° to +50°C
Valve Type
5-Port Solenoid, Plug-In, Base Mounted with 3 Position Closed Center Actuation, Rubber Seal, Negative Common
Voltage, Coil
24 VDC
Series
VQ1000: Manifold Option/With Ejector Unit
An ejector unit can be mounted on the manifold base for a solenoid valve.
Instead of mounting the valve and ejector unit separately, this option
reduces piping, wiring and creates additional space savings.
Dimensions
How to Order
VV5Q11 05C6FUO J
69
D side
VQ1000
Vacuum
release valve
to be indicated alphabetically.
Air supply
valve
Manual override for
supply valve
Manual override for
release valve
Vacuum switch
Others, option symbols:
Number of ejectors
Nil
P
U side
None
With
Note 1) SUP and EXH ports on
Note 2) Individual piping is
Note 3) The manifold with an
Note 4) One vacuum ejector unit
1 to 5
Specify the mounting station by
means of the manifold specifica-
tion sheet.
P
the ejector unit manifold
base are arranged on D-
side alone. The end plate
on the U-side is the same
as that used in the L kit.
provided for the supply
and exhaust ports of the
ejector unit.
ejector unit is mounted
from the U-side.
corresponds to one
station.
86
1 S
94
Example)
VV5Q11-05C6FUO-JP1
Specifications
Maximum Number of Ejector Units
(Max. number of ejector units is subject to the number of valve stations.)
Nozzle diameter (mm)
Max. suction flow rate N (Nl/min)
Max. vacuum pressure (mmHg)
Max. operating pressure (MPa)
Standard supply pressure (MPa)
Operating temperature ( C)
VQ1100-51
VQ1200-51
VVQ1000-J1-51-A
ZSE1-00-15CL
Max. number of
Note 1) Count one ejector unit as one manifold station.
Note 2) The ejector unit is mounted next to the U-side end plate.
Note 3) The U-side end plate is used exclusively for ejector units. (Without P and
Note 4) The dimension of manifold with an ejector unit is different from the
Ejector valve model
Ejector SUP port
ejector units
Note) The max. number of mounted valves applies to double wiring.
1
2
3
4
5
(Release flow
(C6)
adjustment)
R port)
standard dimension. See the formula for calculating the dimensions for
each kit.
Restrictor
Parenthesized numbers apply to single wiring. Please contact SMC for
conditions other than the above or mixed wiring.
.........................
.........................
Ejector valve
....................
...............
F, P, T
11 (20)
10 (16)
VVQ1000„-J„-„„1-A
9 (12)
8 (8)
4 (4)
......
37.2
1 set–Manifold part no.
2 sets–Valve part no. (Stations 1 to 2)
2 sets–Valve part no. (Stations 3 to 4)
1 set–Ejector valve part no.
1 set–Vacuum switch part no.
kit
Max. number of mounted valves
0.7
11
0.7 (High-pressure type 0.8)
Vacuum pressure switch
Indicator light
S, G, J
7 (14)
6 (12)
5 (10)
4 (8)
3 (4)
5 to 50
–630
0.5
kit
VVQ1000„-J„-„„1-B
1.0
20
L
7
6
5
kit

Related parts for VQ1301N-51