IDT82V2084PFG8 IDT, Integrated Device Technology Inc, IDT82V2084PFG8 Datasheet - Page 43

IC LINE INTERFC UNIT 4CH 128TQFP

IDT82V2084PFG8

Manufacturer Part Number
IDT82V2084PFG8
Description
IC LINE INTERFC UNIT 4CH 128TQFP
Manufacturer
IDT, Integrated Device Technology Inc
Type
Line Interface Units (LIUs)r
Datasheet

Specifications of IDT82V2084PFG8

Protocol
E1
Voltage - Supply
3.13 V ~ 3.47 V
Mounting Type
Surface Mount
Package / Case
128-TQFP, 128-VQFP
Screening Level
Industrial
Mounting
Surface Mount
Package Type
TQFP
Operating Temperature (min)
-40C
Operating Temperature (max)
85C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Drivers/receivers
-
Lead Free Status / RoHS Status
Compliant, Lead free / RoHS Compliant
Other names
800-1864-2
82V2084PFG8

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
IDT82V2084PFG8
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
QUAD CHANNEL T1/E1/J1 LONG HAUL/SHORT HAUL LINE INTERFACE UNIT
Table-40 MAINT1: Maintenance Function Control Register 1
Table-41 MAINT2: Maintenance Function Control Register 2
Table-42 MAINT3: Maintenance Function Control Register 3
RIBLBA_L[1:0]
RIBLBD_L[1:0]
TIBLB_L[1:0]
TIBLB[7:0]
Symbol
Symbol
Symbol
ARLP
RLP
DLP
ALP
-
-
(R/W, Address = 0DH,4DH,8DH,CDH)
(R/W, Address = 0BH,4BH,8BH,CBH)
(R/W, Address = 0CH,4CH,8CH,CCH)
7-4
7-6
5-4
3-2
1-0
7-0
Bit
Bit
Bit
3
2
0
1
(000)00001 Defines the user-programmable transmit Inband Loopback activate/deactivate code. The default selection is
Default
Default
Default
0000
00
00
00
01
0
0
0
0
Automatic Remote Loopback Control
Remote loopback enable
Defines the length of the user-programmable receive Inband Loopback activate code contained in RIBLBA regis-
Defines the length of the user-programmable receive Inband Loopback deactivate code contained in RIBLBD reg-
Reserved
= 0: disables Automatic Remote Loopback (normal transmit and receive operation)
= 1: enables Automatic Remote Loopback
= 0: disables remote loopback (normal transmit and receive operation)
= 1: enables remote loopback
Analog loopback enable
= 0: disables analog loopback (normal transmit and receive operation)
= 1: enables analog loopback
Digital loopback enable
= 0: disables digital loopback (normal transmit and receive operation)
= 1: enables digital loopback
Reserved.
Defines the length of the user-programmable transmit Inband Loopback activate/deactivate code contained in
TIBLB register. The default selection is 5 bits length.
= 00: 5-bit activate code in TIBLB [4:0]
= 01: 6-bit activate code in TIBLB [5:0]
= 10: 7-bit activate code in TIBLB [6:0]
= 11: 8-bit activate code in TIBLB [7:0]
ter.
= 00: 5-bit activate code in RIBLBA [4:0]
= 01: 6-bit activate code in RIBLBA [5:0]
= 10: 7-bit activate code in RIBLBA [6:0]
= 11: 8-bit activate code in RIBLBA [7:0]
ister.
= 00: 5-bit deactivate code in RIBLBD [4:0]
= 01: 6-bit deactivate code in RIBLBD [5:0]
= 10: 7-bit deactivate code in RIBLBD [6:0]
= 11: 8-bit deactivate code in RIBLBD [7:0]
00001.
TIBLB[7:0] form the 8-bit repeating code
TIBLB[6:0] form the 7-bit repeating code
TIBLB[5:0] form the 6-bit repeating code
TIBLB[4:0] form the 5-bit repeating code
43
Description
Description
Description
TEMPERATURE RANGES
INDUSTRIAL

Related parts for IDT82V2084PFG8