FM3264-G Ramtron, FM3264-G Datasheet - Page 10

Supervisory Circuits 64K w/Pwr Mon WDT Bat Sw Pwr Fail

FM3264-G

Manufacturer Part Number
FM3264-G
Description
Supervisory Circuits 64K w/Pwr Mon WDT Bat Sw Pwr Fail
Manufacturer
Ramtron
Datasheet

Specifications of FM3264-G

Number Of Voltages Monitored
4
Monitored Voltage
2.6 V or 2.9 V or 3.9 V or 4.4 V
Output Type
Active Low or Bidirectional
Manual Reset
Resettable
Watchdog
Watchdog
Battery Backup Switching
Backup
Power-up Reset Delay (typ)
200 ms
Supply Voltage (max)
5.5 V
Supply Voltage (min)
2.7 V
Supply Current (typ)
1500 uA
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Package / Case
SOIC-14
Minimum Operating Temperature
- 40 C
Power Fail Detection
Yes
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
FM3264-GTR
Manufacturer:
CYPRESS
Quantity:
2 500
Rev. 3.1
July 2010
09h
WTR
POR
LB
WR3-0
00-08h
Reserved – DO NOT USE THIS ADDRESS SPACE
Watchdog Restart & Flags
Watchdog Timer Reset Flag: When the /RST signal is activated by the watchdog the WTR bit will be set to 1. It
must be cleared by the user. Note that both WTR and POR could be set if both reset sources have occurred since
the flags were cleared by the user. Battery-backed. Read/Write (internally set, user can clear bit).
Power-on Reset Flag: When the /RST pin is activated by V
cleared by the user. Note that both WTR and POR could be set if both reset sources have occurred since the flags
were cleared by the user. Battery-backed. Read/Write (internally set, user can clear bit).
Low Backup Flag: On power up, if the VBAK source is below the minimum voltage to operate the event counters,
this bit will be set to 1. The user should clear it to 0 when initializing the system. Battery-backed. Read/Write
(internally set, user can clear bit).
Watchdog Restart: Writing a pattern 1010b to WR3-0 restarts the watchdog timer. The upper nibble contents do
not affect this operation. Writing any pattern other than 1010b to WR3-0 has no effect on the timer. This allows
users to clear the WTR, POR, and LB flags without affecting the watchdog timer. Write-only.
WTR
D7
POR
D6
D5
LB
D4
-
DD
WR3
D3
< V
TP
, the POR bit will be set to 1. It must be
WR2
D2
WR1
D1
FM3204/16/64/256
Page 10 of 21
WR0
D0