FM3264-G Ramtron, FM3264-G Datasheet - Page 21

Supervisory Circuits 64K w/Pwr Mon WDT Bat Sw Pwr Fail

FM3264-G

Manufacturer Part Number
FM3264-G
Description
Supervisory Circuits 64K w/Pwr Mon WDT Bat Sw Pwr Fail
Manufacturer
Ramtron
Datasheet

Specifications of FM3264-G

Number Of Voltages Monitored
4
Monitored Voltage
2.6 V or 2.9 V or 3.9 V or 4.4 V
Output Type
Active Low or Bidirectional
Manual Reset
Resettable
Watchdog
Watchdog
Battery Backup Switching
Backup
Power-up Reset Delay (typ)
200 ms
Supply Voltage (max)
5.5 V
Supply Voltage (min)
2.7 V
Supply Current (typ)
1500 uA
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Package / Case
SOIC-14
Minimum Operating Temperature
- 40 C
Power Fail Detection
Yes
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
FM3264-GTR
Manufacturer:
CYPRESS
Quantity:
2 500
Revision History
Rev. 3.1
July 2010
Revision
0.21
0.2
1.0
2.0
2.1
2.2
2.3
2.4
3.0
3.1
3/18/2008
3/30/2010
7/27/2010
11/25/03
10/25/04
5/22/03
3/30/04
12/8/04
10/5/05
10/2/06
Date
Summary
Fixed package drawing dimensions.
Operating table. Changed V
Changed to Pre-Production status. Added text to Trickle Charger section.
Improved spec limits on V
limits in DC Operating table. Added companion register table with default
values. Added Package Marking Scheme and board footprint. Devices marked
with Date Codes 0440 and higher comply with the revision of the datasheet.
Changed description of POR flag and manual reset (pg. 5, 10). Added notes to
Absolute Maximum Ratings.
Rewrote section on battery backup. Added comment about unused CNT pins.
Removed -S packaging option which is Not Recommended for New Designs.
Added ESD and MSL ratings which are valid for Date Codes 0440 and higher.
Not recommended for new designs. As an alternative, use FM3127xB for 5V
designs or FM31L27xB for 3V designs.
Changed to Production status. These products are no longer Not
Recommended for New Designs (NRND). Updated ESD ratings. Updated lead
temperature rating in Abs Max table. Removed battery insertion sequence text
(p. 6). The sequence is no longer necessary for devices with date codes after
0701.
Removed text indicating that a manual reset sets the POR flag.
Initial release.
Changed product status to Preliminary. Added V
TP
HYS
, V
limits. Added “green” package.
PFI
, and V
HYS
parameters and changed V
TP
and V
PFI
FM3204/16/64/256
parameters in DC
Page 21 of 21
IH
max

Related parts for FM3264-G