SU2200RMXLTNET APC, SU2200RMXLTNET Datasheet - Page 43

no-image

SU2200RMXLTNET

Manufacturer Part Number
SU2200RMXLTNET
Description
UPS - Uninterruptible Power Supplies APC Smart-UPS XL 2200VA RM 5U 208V
Manufacturer
APC
Datasheet

Specifications of SU2200RMXLTNET

Power Rating
1600 W
Output Voltage Rating
208 V
Number Of Outlets
5
Interface Port
DB-9 RS-232, SmartSlot
Runtime (full Load)
10 min
Runtime (half Load)
34 min
Topology
Online
Tower / Rackmount
Rackmount
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
3. Retrieve the other four-wire, yellow jumper harness. Plug the “fe-
4. Retrieve the 3-wire jumper harness (Figure 3-1, item #10). Plug
7. Cut the wire tie securing the wires to connector #1 and separate
8. Double check all connections. Make sure all connections are firmly
5.4.3 Connecting External Wiring to the UPS
The wire harness assembly provides a terminal block equipped with
screw terminals to attach input and output wiring. Follow the proce-
dure below to connect input and output wiring to the wire harness as-
sembly.
Connect Input Wiring to the Wire Harness Assembly
CAUTION: Make sure input wiring is not live!!
1. Locate the input panel from the hardwire kit (Figure 3-1, item #6)
2. Remove approximately 5 inches of outer jacket from the end of the
male” end of the jumper harness into connector #2. Connect the
“male” end of the jumper harness to the 4-pin plug located inside
the UPS. (Connector
the “female” end of the jumper harness into connector #3. Connect
the “male” end of the jumper harness to the 3-pin output connec-
tor inside the UPS. (Connector
the wires.
a. Plug connector #1 into the 4-pin transformer connector inside
b. Connect the two “push-on” terminals to the circuit breaker
c. Use a green screw from the hardware bag to secure the green
locked together. Pay close attention that connectors #2 and #4 are
connected correctly.
and remove the appropriate size knockout from the panel. Install a
cable clamp so that it can be tightened from the outside of the unit
once the panel is installed.
input cable. Separate the three wires (white, black and green). Strip
the insulation from the end of each wire so that approximately
3/8" of bare wire is exposed. Route the input wiring through the
input panel so that the panel can be installed correctly after the
connections have been made. Make sure that the cable clamp is in-
stalled such that the screws will be located outside of the unit.
the UPS. (Connector
that was removed from the original output panel. (Section
5.4.1)
ground wire to one of the ground screws holes on the mount-
ing bracket. (See Figure 5-28)
in Figure 5-24)
in Figure 5-24)
in Figure 5-24)
41