M29W320DT70N6E Micron Technology Inc, M29W320DT70N6E Datasheet - Page 17

no-image

M29W320DT70N6E

Manufacturer Part Number
M29W320DT70N6E
Description
Manufacturer
Micron Technology Inc
Datasheet

Specifications of M29W320DT70N6E

Cell Type
NOR
Density
32Mb
Access Time (max)
70ns
Interface Type
Parallel
Boot Type
Top
Address Bus
22/21Bit
Operating Supply Voltage (typ)
3/3.3V
Operating Temp Range
-40C to 85C
Package Type
TSOP
Program/erase Volt (typ)
2.7 to 3.6/12V
Sync/async
Asynchronous
Operating Temperature Classification
Industrial
Operating Supply Voltage (min)
2.7V
Operating Supply Voltage (max)
3.6V
Word Size
8/16Bit
Number Of Words
4M/2M
Supply Current
10mA
Mounting
Surface Mount
Pin Count
48
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M29W320DT70N6E
Manufacturer:
ST
Quantity:
1 500
Part Number:
M29W320DT70N6E
Manufacturer:
ST
Quantity:
3 198
Part Number:
M29W320DT70N6E
Manufacturer:
ST
Quantity:
3 198
Part Number:
M29W320DT70N6E
Manufacturer:
Numonyx
Quantity:
11 520
Part Number:
M29W320DT70N6E
Manufacturer:
ST
0
Part Number:
M29W320DT70N6E
Manufacturer:
MICRON/ST
Quantity:
20 000
4
4.1
4.2
Command Interface
All Bus Write operations to the memory are interpreted by the Command Interface.
Commands consist of one or more sequential Bus Write operations. Failure to observe a
valid sequence of Bus Write operations will result in the memory returning to Read mode.
The long command sequences are imposed to maximize data security.
The address used for the commands changes depending on whether the memory is in 16-
bit or 8-bit mode. See either
used, for a summary of the commands.
Read/Reset command
The Read/Reset command returns the memory to its Read mode where it behaves like a
ROM or EPROM, unless otherwise stated. It also resets the errors in the Status Register.
Either one or three Bus Write operations can be used to issue the Read/Reset command.
The Read/Reset Command can be issued, between Bus Write cycles before the start of a
program or erase operation, to return the device to read mode. Once the program or erase
operation has started the Read/Reset command is no longer accepted. The Read/Reset
command will not abort an Erase operation when issued while in Erase Suspend.
Auto Select command
The Auto Select command is used to read the Manufacturer Code, the Device Code and the
Block Protection Status. Three consecutive Bus Write operations are required to issue the
Auto Select command. Once the Auto Select command is issued the memory remains in
Auto Select mode until a Read/Reset command is issued. Read CFI Query and Read/Reset
commands are accepted in Auto Select mode, all other commands are ignored.
From the Auto Select mode the Manufacturer Code can be read using a Bus Read
operation with A0 = V
The Manufacturer Code for Numonyx is 0020h.
The Device Code can be read using a Bus Read operation with A0 = V
other address bits may be set to either V
22CAh and for the M29W320DB is 22CBh.
The Block Protection Status of each block can be read using a Bus Read operation with A0
= V
may be set to either V
Data Inputs/Outputs DQ0-DQ7, otherwise 00h is output.
IL
, A1 = V
IH
, and A12-A20 specifying the address of the block. The other address bits
IL
IL
and A1 = V
or V
Table
IH
. If the addressed block is protected then 01h is output on
4, or
IL
. The other address bits may be set to either V
Table
IL
or V
5, depending on the configuration that is being
IH
. The Device Code for the M29W320DT is
IH
and A1 = V
IL
IL
or V
. The
17/56
IH
.

Related parts for M29W320DT70N6E