N28F001BXT150 Intel, N28F001BXT150 Datasheet - Page 20

no-image

N28F001BXT150

Manufacturer Part Number
N28F001BXT150
Description
Manufacturer
Intel
Datasheet

Specifications of N28F001BXT150

Density
1Mb
Access Time (max)
150ns
Interface Type
Parallel
Boot Type
Top
Address Bus
17b
Operating Supply Voltage (typ)
5V
Operating Temp Range
0C to 70C
Package Type
PLCC
Program/erase Volt (typ)
11.4 to 12.6V
Sync/async
Asynchronous
Operating Temperature Classification
Commercial
Operating Supply Voltage (min)
4.5V
Operating Supply Voltage (max)
5.5V
Word Size
8b
Number Of Words
128K
Supply Current
30mA
Mounting
Surface Mount
Pin Count
32
Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
N28F001BXT150
Manufacturer:
INT
Quantity:
3 000
Part Number:
N28F001BXT150
Manufacturer:
INT
Quantity:
3 000
Part Number:
N28F001BXT150
Manufacturer:
INTEL
Quantity:
5 510
28F001BX
20
FULL STATUS CHECK PROCEDURE
Check if Desired
Block Address
Block Address
SR.4, 5 = 1? =
Register Data
Read Status
Read Status
(See Above)
Block Erase
Block Erase
Write D0H,
Write 20H,
Completed
Successful
Full Status
SR.7 = 1?
SR.3 = 0?
SR.5 = 0?
Register
Start
Yes
No
Yes
Yes
Yes
No
No
No
Command Seq. Error
Block Erase Error
Figure 9. 28F001BX Block Erase Flowchart
V
No
PP
Suspend
Erase?
Range Error
Erase Suspend
Yes
Loop
Repeat for subsequent blocks.
Full status check can be done after each block, or after a sequence of
blocks.
Write FFH after the last block erase operation to reset the device to
read array mode.
SR.3 must be cleared, if set during an erase attempt, before further
attempts are allowed by the write state machine.
SR.5 is only cleared by the Clear Status Register command in cases
where multiple blocks are erased before full status is checked.
If an error is detected, clear the status register before attempting retry
or other error recovery.
Operation
Operation
Standby
Standby
Standby
Standby
Write
Write
Read
Bus
Bus
Erase Setup
Command
Command
Erase
Data = 20H
Addr = Within Block to Be Erased
Data = D0H
Addr = Within Block to Be Erased
Status Register Data
Toggle OE# or CE# to Update
Status Register
Check SR.7
1 = Ready
0 = Busy
Check SR.3
1 = V
Check SR.4, 5
Both 1 = Command Sequence
Error
Check SR.5
1 = Block Erase Error
PP
Low Detect
Comments
Comments
0406_09

Related parts for N28F001BXT150