M29W800AT90M1 Micron Technology Inc, M29W800AT90M1 Datasheet - Page 33

no-image

M29W800AT90M1

Manufacturer Part Number
M29W800AT90M1
Description
Manufacturer
Micron Technology Inc
Datasheet

Specifications of M29W800AT90M1

Cell Type
NOR
Density
8Mb
Access Time (max)
90ns
Interface Type
Parallel
Boot Type
Top
Address Bus
20/19Bit
Operating Supply Voltage (typ)
3.3V
Operating Temp Range
0C to 70C
Package Type
SO
Program/erase Volt (typ)
2.7 to 3.6V
Sync/async
Asynchronous
Operating Temperature Classification
Commercial
Operating Supply Voltage (min)
2.7V
Operating Supply Voltage (max)
3.6V
Word Size
8/16Bit
Number Of Words
1M/512K
Supply Current
10mA
Mounting
Surface Mount
Pin Count
44
Lead Free Status / Rohs Status
Supplier Unconfirmed

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M29W800AT90M1
Manufacturer:
ST
Quantity:
58
Part Number:
M29W800AT90M1
Manufacturer:
ADI
Quantity:
20 000
Part Number:
M29W800AT90M1
Manufacturer:
ST
0
Part Number:
M29W800AT90M1T
Manufacturer:
ST
0
SECURITY PROTECTION MEMORY AREA
The M29W800A features a security protection
memory area. It consists of a memory block of 256
bytes or 128 words which is programmed in the ST
factory to store a unique code that uniquely identi-
fies the part.
This memory block can be read by using the Read
Security Data instruction (RDS) as shown in Table
23.
Table 23. Security Block Instruction
Note: 1. Address bits A10-A19 are don't care for coded address inputs.
Figure 17. Security Block Address Table
Mne.
RDS
2. Data bits DQ8-DQ15 are don't care for coded address inputs.
Read
Security
Data
Instr.
000FFh
0007Fh
00000h
00000h
Cyc.
1
TOP BOOT BLOCK
TOP BOOT BLOCK
Memory Block
Memory Block
Addr.
Data
Security
Security
(2)
(1)
WORD Organisation (x16)
Unlock Cycle
BYTE Organisation (x8)
1st Cyc.
AAh
B8h
Read Security Data (RDS) Instruction. This RDS
uses a single write cycle instruction: the command
B8h is written to the address AAh. This sets the
memory to the Read Security mode. Any succes-
sive read attempt will output the addressed Secu-
rity byte until a new write cycle is initiated.
Read OTP Data until a new write cycle is initiated.
BOTTOM BOOT BLOCK
BOTTOM BOOT BLOCK
Memory Block
Memory Block
Security
Security
M29W800AT, M29W800AB
2nd Cyc.
AI02746
0E0FFh
0E000h
0E01Fh
0E000h
33/40