F10
Note:
(2) Press the UP/DOWN selection buttons to adjust the threshold.
Plain Measurement
Press the teach/display button to change the display (DEV-AVE).
Adjust the threshold to the most suitable level by monitoring the level indicator.
Altered threshold values will not be saved unless the mode selector is changed once to either RUN or TEACH.
Pattern Measurement
In wide mode, the pattern with the lowest degree of conformance among the three models is selected.
Plain Measurement
Set the threshold values for both DEV (deviation level) and AVE (average density). If either is lower than the threshold value, the discrimi-
nation result will be set to OFF.
Use the DIP switch to turn ON and OFF the output signal. Refer to Nomenclature for details.
Bank No.
·
·
Status indicators (F10-C20/C25)
Status indicator (F10-C30/C35/C50/C55)
Displays the
mode indicating
the current level.
Press the teach/
display button
Closer to model
in appearance
Plain measurement
Turns ON if the measurement value
is higher than the threshold.
The result indicator and output
signal are ON. (See note.)
PATT
Returns to bank number
display if no operation is
performed for 5 seconds.
Not closer to model
in appearance
Threshold value
Returns to bank number
display if no operation is
performed for 5 seconds.
Turns OFF if the measurement
value is lower than the threshold.
The result indicator and output
signal are OFF. (See note.)
AVE (difference from taught
average density)
Deviation level
Difference from average
density during teaching
Plain measurement
Plain measurement
DEV (deviation level)
Press the
Display
Button
Threshold value
Difference from
registered pattern
is small
Difference from
registered pattern
is great
Average density
Deviation
level is
small
Deviation
level is
great
Increases the smaller the
deviation level compared
with the taught average
density.
Increases the smaller
the deviation level.
AVE lit
DEV lit