F10-S30R Omron, F10-S30R Datasheet - Page 3

25C4243

F10-S30R

Manufacturer Part Number
F10-S30R
Description
25C4243
Manufacturer
Omron
Datasheet

Specifications of F10-S30R

Sensing Range
90mm To 110mm
Peak Reflow Compatible (260 C)
No
Terminal Type
Wire Leaded
Supply Current Max
150mA
Supply Voltage Max
19.8VDC
Sensor Terminals
Cable
Leaded Process Compatible
No
Rohs Compliant
No
F10
Amplifiers
Performance Specifications
General Specifications
10
Model
Output type
Measurement item
Number of models
Bank selection
Automatic teaching
function
Model size
Measurement processing
time
Output signal (2 points)
Output selection
Input signal
C20/C25 (4 points)
C30/C35/C50/C55
(7 points)
Head interface (1 channel)
Indicators
Operation interface
Ambient temperature
Ambient humidity
Operating environment
Input power supply
Current consumption
Insulation resistance
Dielectric strength
Degree of protection
Vibration resistance
Shock resistance
Connection
Casing material
Weight (when packed)
Accessories provided
Item
Item
F10-C20/C30/C50
NPN
Pattern measurement/plain measurement
C20/C25: 1 model, C30/C35/C50/C55: 1 model per bank
C20/C25: None, C30/C35/C50/C55: 8 banks
Yes
Normal or wide mode (selectable)
3.6 ms in normal mode and 10.8 ms in wide mode (continuous operation)
Control output and enable output: NPN open
collector with load voltage of 30 V max., load
current of 50 mA max. and residual voltage of 1.2
V max.
Matching output: ON when image matches the registered model.
Not matching output: ON when image does not match the registered model.
External trigger input (with minimum pulse width of
1 ms), continuous measurement input, moving
object teaching input, or stationary object teaching
input
Input is ON:
Input is OFF: Open or input voltage of 5 V min.
Available Head:
Result indicator:
Level indicators:
Threshold indicators:
Status indicators:
Teach/display button (TEACH/DISPLAY), UP/DOWN selection buttons, mode selector
(TEACH/MON/RUN), 5 DIP switch pins: Automatic teaching (OFF/ON), model size (NORMAL/WIDE),
OFF-delay timer (OFF/ON), matching/not matching (output ON for matching object/non-matching object),
and external input (C50/C55 only) (LINE: To use the input line for external inputs in RUN mode;
RS-232C/422: To use serial communications for external inputs in RUN mode)
Operating:
Storage:
Operating:
Storage:
With no corrosive gas
21.6 to 26.4 VDC (with ripple)
300 mA max.
20 MW min. (at 500 VDC)
1,000 VAC at 50/60 Hz for 1 min
IEC 60529 IP40
10 Hz to 150 Hz, half-amplitude of 0.75 mm max. or 100 m/s
directions
Peak acceleration: 300 m/s
Prewired (standard cable length: 2 m)
ABS
Approx. 300 g (Unit: approx. 200 g (including cable))
Instruction manual
Short-circuited to 0 V with
short-circuit current of 1 mA max. or
1.5 V max.
(Max. input voltage: +26.4 VDC)
0°C to 50°C (with no icing or condensation)
35% to 85% (with no condensation)
35% to 85% (with no condensation)
- -25°C to 65°C (with no icing or condensation)
F10-S30R, F10-S15R, or F10-S05R
1 orange LED
8 green LEDs
7 red LEDs
3 on the C20/C25, or 7 on the C30/C35/C50/C55
2
3 times each in X, Y, and Z directions
Specification
Specification
F10-C25/C35/C55
PNP
Control output and enable output: PNP open
collector with load voltage of 30 V max., load
current of 50 mA max. and residual voltage of 2.0
V max.
External trigger input (with minimum pulse width of
1 ms), continuous measurement input, moving
object teaching input, or stationary object teaching
input
Input is ON:
Input is OFF: Open or input voltage of 5 V max.
2
max. for 32 min each in X, Y, and Z
Short-circuited to Vcc or 9 V min.
(Max. input voltage: +26.4 VDC)
F10