AT89C51ID2-SLSIM Atmel, AT89C51ID2-SLSIM Datasheet - Page 82

no-image

AT89C51ID2-SLSIM

Manufacturer Part Number
AT89C51ID2-SLSIM
Description
C51ID2 64KF TWI 32KHZ PLCC44 3-5.5V IND.
Manufacturer
Atmel
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT89C51ID2-SLSIM
Manufacturer:
ATMEL
Quantity:
5 510
Part Number:
AT89C51ID2-SLSIM
Manufacturer:
TI
Quantity:
5 510
Description
4289C–8051–11/05
SDA
SCL
The CPU interfaces to the 2-wire logic via the following four 8-bit special function regis-
ters: the Synchronous Serial Control register (SSCON; Table 71), the Synchronous
Serial Data register (SSDAT; Table 72), the Synchronous Serial Control and Status reg-
ister (SSCS; Table 73) and the Synchronous Serial Address register (SSADR Table 76).
SSCON is used to enable the TWI interface, to program the bit rate (see Table 64), to
enable slave modes, to acknowledge or not a received data, to send a START or a
STOP condition on the 2-wire bus, and to acknowledge a serial interrupt. A hardware
reset disables the TWI module.
SSCS contains a status code which reflects the status of the 2-wire logic and the 2-wire
bus. The three least significant bits are always zero. The five most significant bits con-
tains the status code. There are 26 possible status codes. When SSCS contains F8h,
no relevant state information is available and no serial interrupt is requested. A valid sta-
tus code is available in SSCS one machine cycle after SI is set by hardware and is still
present one machine cycle after SI has been reset by software. to Table 70. give the
status for the master modes and miscellaneous states.
SSDAT contains a byte of serial data to be transmitted or a byte which has just been
received. It is addressable while it is not in process of shifting a byte. This occurs when
2-wire logic is in a defined state and the serial interrupt flag is set. Data in SSDAT
remains stable as long as SI is set. While data is being shifted out, data on the bus is
simultaneously shifted in; SSDAT always contains the last byte present on the bus.
SSADR may be loaded with the 7-bit slave address (7 most significant bits) to which the
TWI module will respond when programmed as a slave transmitter or receiver. The LSB
is used to enable general call address (00h) recognition.
Figure 31 shows how a data transfer is accomplished on the 2-wire bus.
Figure 31. Complete Data Transfer on 2-wire Bus
The four operating modes are:
Data transfer in each mode of operation is shown in Table to Table 70 and Figure 32. to
Figure 35.. These figures contain the following abbreviations:
S : START condition
R : Read bit (high level at SDA)
Master Transmitter
Master Receiver
Slave transmitter
Slave receiver
start
condition
S
MSB
1
2
7
8
signal from receiver
acknowledgement
ACK
9
while interrupts are serviced
clock line held low
1
2
3-8
ACK
signal from receiver
AT89C51ID2
9
acknowledgement
condition
stop
P
82

Related parts for AT89C51ID2-SLSIM