AT89C51ID2-SLSIM Atmel, AT89C51ID2-SLSIM Datasheet - Page 84

no-image

AT89C51ID2-SLSIM

Manufacturer Part Number
AT89C51ID2-SLSIM
Description
C51ID2 64KF TWI 32KHZ PLCC44 3-5.5V IND.
Manufacturer
Atmel
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT89C51ID2-SLSIM
Manufacturer:
ATMEL
Quantity:
5 510
Part Number:
AT89C51ID2-SLSIM
Manufacturer:
TI
Quantity:
5 510
Slave Receiver Mode
Slave Transmitter Mode
4289C–8051–11/05
When the slave address and the direction bit have been transmitted and an acknowl-
edgement bit has been received, the serial interrupt flag is set again and a number of
status code in SSCS are possible. There are 40h, 48h or 38h for the master mode and
also 68h, 78h or B0h if the slave mode was enabled (AA=logic 1). The appropriate
action to be taken for each of these status code is detailed in Table . This scheme is
repeated until a STOP condition is transmitted.
SSIE, CR2, CR1 and CR0 are not affected by the serial transfer and are referred to
Table 7 to Table 11. After a repeated START condition (state 10h) the TWI module may
switch to the master transmitter mode by loading SSDAT with SLA+W.
In the slave receiver mode, a number of data bytes are received from a master transmit-
ter (Figure 34). To initiate the slave receiver mode, SSADR and SSCON must be loaded
as follows:
Table 63. SSADR: Slave Receiver Mode Initialization
The upper 7 bits are the address to which the TWI module will respond when addressed
by a master. If the LSB (GC) is set the TWI module will respond to the general call
address (00h); otherwise it ignores the general call address.
Table 64. SSCON: Slave Receiver Mode Initialization
CR0, CR1 and CR2 have no effect in the slave mode. SSIE must be set to enable the
TWI. The AA bit must be set to enable the own slave address or the general call address
acknowledgement. STA, STO and SI must be cleared.
When SSADR and SSCON have been initialised, the TWI module waits until it is
addressed by its own slave address followed by the data direction bit which must be at
logic 0 (W) for the TWI to operate in the slave receiver mode. After its own slave
address and the W bit have been received, the serial interrupt flag is set and a valid sta-
tus code can be read from SSCS. This status code is used to vector to an interrupt
service routine.The appropriate action to be taken for each of these status code is
detailed in Table . The slave receiver mode may also be entered if arbitration is lost
while TWI is in the master mode (states 68h and 78h).
If the AA bit is reset during a transfer, TWI module will return a not acknowledge (logic 1)
to SDA after the next received data byte. While AA is reset, the TWI module does not
respond to its own slave address. However, the 2-wire bus is still monitored and
address recognition may be resume at any time by setting AA. This means that the AA
bit may be used to temporarily isolate the module from the 2-wire bus.
In the slave transmitter mode, a number of data bytes are transmitted to a master
receiver (Figure 35). Data transfer is initialized as in the slave receiver mode. When
SSADR and SSCON have been initialized, the TWI module waits until it is addressed by
bit rate
CR2
A6
SSIE
A5
1
STA
A4
0
own slave address
STO
A3
0
A2
SI
0
AA
A1
1
AT89C51ID2
bit rate
CR1
A0
bit rate
CR0
GC
84