SAM3U2C Atmel Corporation, SAM3U2C Datasheet - Page 683

no-image

SAM3U2C

Manufacturer Part Number
SAM3U2C
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of SAM3U2C

Flash (kbytes)
128 Kbytes
Pin Count
100
Max. Operating Frequency
96 MHz
Cpu
Cortex-M3
# Of Touch Channels
28
Hardware Qtouch Acquisition
No
Max I/o Pins
57
Ext Interrupts
57
Usb Transceiver
1
Quadrature Decoder Channels
1
Usb Speed
Hi-Speed
Usb Interface
Device
Spi
4
Twi (i2c)
1
Uart
4
Ssc
1
Sd / Emmc
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
8
Adc Resolution (bits)
12
Adc Speed (ksps)
384
Resistive Touch Screen
No
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
36
Self Program Memory
YES
External Bus Interface
1
Dram Memory
No
Nand Interface
Yes
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.8/3.3
Operating Voltage (vcc)
1.62 to 3.6
Fpu
No
Mpu / Mmu
Yes / No
Timers
3
Output Compare Channels
3
Input Capture Channels
3
Pwm Channels
4
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes
34.6.6
Name:
Address:
Access:
• RXRDY: Receiver Ready
0 = No character has been received since the last read of the UART_RHR or the receiver is disabled.
1 = At least one complete character has been received, transferred to UART_RHR and not yet read.
• TXRDY: Transmitter Ready
0 = A character has been written to UART_THR and not yet transferred to the Shift Register, or the transmitter is disabled.
1 = There is no character written to UART_THR not yet transferred to the Shift Register.
• ENDRX: End of Receiver Transfer
0 = The End of Transfer signal from the receiver Peripheral Data Controller channel is inactive.
1 = The End of Transfer signal from the receiver Peripheral Data Controller channel is active.
• ENDTX: End of Transmitter Transfer
0 = The End of Transfer signal from the transmitter Peripheral Data Controller channel is inactive.
1 = The End of Transfer signal from the transmitter Peripheral Data Controller channel is active.
• OVRE: Overrun Error
0 = No overrun error has occurred since the last RSTSTA.
1 = At least one overrun error has occurred since the last RSTSTA.
• FRAME: Framing Error
0 = No framing error has occurred since the last RSTSTA.
1 = At least one framing error has occurred since the last RSTSTA.
• PARE: Parity Error
0 = No parity error has occurred since the last RSTSTA.
1 = At least one parity error has occurred since the last RSTSTA.
6430E–ATARM–29-Aug-11
6430E–ATARM–29-Aug-11
PARE
31
23
15
7
UART Status Register
FRAME
30
22
14
UART_SR
0x400E0614
Read-only
6
OVRE
29
21
13
5
RXBUFF
ENDTX
28
20
12
4
TXBUFE
ENDRX
27
19
11
3
26
18
10
2
SAM3U Series
SAM3U Series
TXEMPTY
TXRDY
25
17
9
1
RXRDY
24
16
8
0
683