SAA7146AH/V4,557 NXP Semiconductors, SAA7146AH/V4,557 Datasheet - Page 55

IC VIDEO SPCI BRIDGE HP 160-QFP

SAA7146AH/V4,557

Manufacturer Part Number
SAA7146AH/V4,557
Description
IC VIDEO SPCI BRIDGE HP 160-QFP
Manufacturer
NXP Semiconductors
Type
Video Bridger
Datasheet

Specifications of SAA7146AH/V4,557

Package / Case
160-QFP
Applications
DTV
Mounting Type
Surface Mount
Maximum Operating Temperature
+ 70 C
Minimum Operating Temperature
0 C
Mounting Style
SMD/SMT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
568-1318
935269343557
SAA7146AHBB

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SAA7146AH/V4,557
Manufacturer:
NXP Semiconductors
Quantity:
10 000
Philips Semiconductors
Table 53 Field interval definitions for D1 (CCIR 656) SAV and EAV codes; note 1
Note
1. Signals F and V change state synchronously with the end of active video timing reference code at the beginning of
7.8.6.1
Field detection modes:
2004 Aug 25
handbook, full pagewidth
V-digital field blanking
Field 1; start (V = 1)
Field 1; finish (V = 0)
Field 2; start (V = 1)
Field 2; finish (V = 0)
F-digital field identification
Field 1; F = 0
Field 2; F = 1
Direct mode: FLD signal detected from incoming H/V signals, for timing behaviour see Figs. 11 and 12.
Forced toggle: FLD signal regularly synchronized to source, but will never stay more than two fields with the same ID.
The circuit expects to detect a field change with every vertical reference edge, if the field does not change (field error),
the circuit change the field ID automatically. If the circuit switch to the wrong sequence i. e. at the beginning of
processing, it will be synchronized after one second where no field error has occurred.
Free toggle: FLD signal toggles with every vertical reference edge, independent of source FID.
Multimedia bridge, high performance
Scaler and PCI circuit (SPCI)
the digital line.
FLD-DMSD
V-DMSD
FLD
LLC
Field detection control
HS
VS
DEFINITION
Fig.11 Timing of field detection EVEN-to-ODD for direct mode.
Line 624
Line 23
Line 311
Line 336
Line 1
Line 313
625 LINES
55
Line 1
Line 10
Line 264
Line 273
Line 4
Line 266
525 LINES
Product specification